Type: Welding / wire type, with left column.
Drive rod: needle shaped button type.
Terminal specification: welding.
Contact specifications: 1c.
The minimum size of the long stroke type can be reliably switch
The body part size is 78% of the previous generation product, which is beneficial to the miniaturization of the equipment.
No swing bars are also used for easy long stroke specifications (OT reference value: 1
F2EL-X2F2-DS3SL4mm).
Without harmful substances to the environment, the lead type has also been lead-free. Rated voltage: 115 V .
Permitted voltage fluctuation range: 85% to 110% rated voltage.
Frequency: 50/60 Hz.
Rated current: 50 Hz, 0.420 A; 60 Hz, 0.370 A .
Rated input: 50 Hz, 43 W; 60 Hz, 40 W.
Rated rotational speed: 50 Hz, 2800 r/min; 60 Hz, 3250 r/min.
Maximum flow rate: 50 Hz, 5.0 m3/min; 60 Hz, 5.8 m3/min.
Maximum static pressure: 50 Hz, 118 Pa; 60 Hz, 88 Pa.
Noise: 50 Hz, 52 dB; 60 Hz, 56 dB.
Optimum Cooling with a Comprehensive.
Lineup of Axial Fans.
Low noise level, long service life, and resistance to the,
environment.
Shaft supported by ball bearings for highly-reliable operation.
Plastic-bladed models (44 type) and metal-bladed models,
(28 type) included in series.
R87T-A@A15H-WR Water-resistant AC Axial Fans,
(IP X7 degree of protection) added to series.
CE marking compliant and certified by UL and CSA.
Note: The compliant standards and certified safety standards depend on the,
product. Check the information given for available models of Axial fans and,
the information in Characteristics. C500-OC I/O Unit Transistor Output 16 pts C500-OC223-E(3G2A5-OC223-E).
AC250/DC24V 2A.Category: incidental cover type.
Structure: DIN guide rail mounting type.
Capacity: 50W.
Output voltage: 5V.
Output current: 10A.
Built in OMRON''s original new under voltage detection function of small size,
Also contribute to the miniaturization of the device.
Built in support for determining the abnormal causes of the new under voltage detection function.
(S8VM- - P - 24A - racy type)
Power failure detection function with built-in hint output voltage abnormity.
(type 300/600/1500W)
A total of 8 kinds of capacity of 29 models, a complete range of products.
Meet RoHS instructions including lead free.
Humanized design of anti - shedding screw for terminal stage.
(except for the 300/600/1500W output terminals)
Support finger touch protection to prevent electric shock.
DIN guide rail simple installation.
Safety standards: CSA, C22.2 No.14/No.60950-1 UL508/60950-1,
EN50178, EN60950-1.
(300/600/1500W type, safety standard is not applicable when the fan is replaced by the customer.)
Meet F47-0200 SEMI standards. (200V input)
High harmonic current limit: EN61000-3-2. (except for type 15/30W)
"
F2EL-X2F2-DS3SL Operation manual/Instructions/Model selection sample download link: