Ontology: program type.
Size: 48 x 96mm.
Type: control valve control type (1 input).
Control mode: 1 channel position ratio control.
Output (control / transfer) points: relay output (open 1 + 1) + current 1.
Output (SUB) points: 4 points.
Event input points: -.
Serial communication: RS-485.
New high speed, high precision digital regulator (Cheng Xuxing)!
Can be set up to 32 kinds of procedures.
1 units can be coordinated to run up to 4 channels
F3SG-4RA1360-14
High speed acquisition of 50ms.
With CX-Thermo on the computer easily set. Ratings: 1 A at 125 VAC.
LED indicator: With indicator.
Actuator: Center roller lever.
Many Models Including Roller Lever.
Switches are Only 16-mm Thick with Connector.
New center roller lever models that enable ganged mounting.
of up to 6 Switches.
Cable connectors for easy Switch replacement.
Triple-seal construction to provide IEC IP67 degree of protection.
Operation indicators available for easy monitoring,
(standard indicator is lit when Switch is not operating).
Approved by UL and CSA.
(Ask your OMRON representative for Information on approved models.)
Outputs: Time-limit contact.
Supply voltage: 100 to 120 VAC; 200 to 240 VAC.
8-pin models.
DIN 48 × 48-mm Star-delta Timer.
A wide star-time range (up to 120 seconds) and star-delta.
transfer time range (up to 1 seconds). Type of drive rod: roller plunger type.
Conduit size: single catheter type, M20.
Built in switch structure: slow motion (1NC/1NO).
Safety limit switch in accordance with global standard EN 50047.
The contact constitutes a complete variety, there is a single point of specification (1NC) and double contact specifications (1NC/1NO, 2NC).
Forced open action structure.
The slow moving contact structure is adopted to ensure that the contact distance is 4mm.
Elevator and escalator can be used. Isolation: Phototriac coupler.
Zero cross function: Yes.
Indicator: Yes.
Rated output load: 20 A at 200 to 480 VAC.
Rated input voltage: 12 to 24 VDC.
Extremely Thin Relays Integrated with Heat Sinks.
Downsizing achieved through optimum design of heat sink.
Mounting possible via screws or via DIN track.
Close mounting possible for linking terminals.
(Except for G3PA-260B-VD and G3PA-450B-VD-2.)
Applicable with 3-phase loads.
Replaceable power element cartridges.
Comply with VDE 0160 (finger protection),
with a dielectric strength of 4,000 V between input and load.
Certified by UL, CSA, and VDE (reinforced insulation).
F3SG-4RA1360-14 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=F3SG-4RA1360-14&select=5