LK Automation Limited LK Automation Limited
Brand Sort: OMRON
Home >> Price
F3SN-A0937P40 Pirce
No PHOTO
OMRON F3SN-A0937P40
Model: PY (back-mounting), page 15, Wrapping terminals.
Number of pins: 11 pins.
A Wide Variety of Square and,
Round Sockets in Front-mounting,
and Back-mounting Models,
Models available with finger protection.
Hold-down Clips and Socket Bridges for PYF Sockets,
are also available.
New screwless models available. Actuator: Plunger.
Housing color: White.
Contact form: SPST-NO.
A Switch with Crimp-type F3SN-A0937P40
Connectors Reduces.
Wiring Work. 9 mm long.
stroke (plunger model).
Choose from plunger or lever as the actuator type.
Crimp-type connector offers an easy wiring work and efficiency.
Snap-fit attachment for easy installation.
Providing long stroke with its unique mechanism.
Variety of color models available. Input capacity: 16 points.
Internal I/O common: NPN.
ON voltage: 15 VDC min.
(between each input terminal and the V terminal)
OFF voltage: 5 VDC max.
(between each input terminal and the V terminal)
OFF current: 1.0 mA max.
Input current: 6.0 mA max./input (at 24-VDC),
3.0 mA min./input (at 17-VDC).
ON delay: 0.1 ms max.
OFF delay: 0.2 ms max.
Input filter value: Without filter, 0.5 ms, 1 ms,
2 ms, 4 ms, 8 ms, 16 ms, 32 ms. (Default setting: 1 ms)
Number of circuits per common: 8 points/common.
Input indicators: LED display (yellow).
Isolation method: Photocoupler isolation.
I/O power supply method: Supply by I/O power supply.
Input device supply current: 100 mA/point.
Unit power supply current consumption: 90 mA max.
(for 20.4 to 26.4-VDC power supply voltage)
I/O power supply current consumption: 5 mA max.
(for 20.4 to 26.4-VDC power supply voltage)
Weight: 370 g max.
Expansion functions: No.
Short-circuit protection function: No.
A common terminal is provided for each contact.
It eliminate the needs for relay terminal blocks.
It is unnecessary to share the common terminal,
among multiple contacts.
Easy-to-find wiring locations.
Detachable screw terminal block facilitates the maintenance.
Input response time can be switched for high-speed processing.
Selectable node address setting methods: setting with rotary,
switch and with tool software.
When setting the nodes with rotary switch, setting is easy and,
node identification becomes possible for maintenance.
F3SN-A0937P40 Operation manual/Instructions/Model selection sample download link: /searchDownload.html?Search=F3SN-A0937P40&select=5