Type: CJ1 Special I/O Unit.
Connected ID System: V680 Series; 1 Head.
External power supply: --.
No. of unit numbers used: 1 unit number.
Current consumption: 5V, 0.26A;
24V, 0.13A; External, --.
Communication Unit Dedicated for RFID V680,
Allowing Direct Connection to OMRON PLC CJ/
CS/NJ-series.
Communication unit for connecting RFID V680-series,
which can be used around the world, directly to PLC
F3WN-X0922N25
Allows batch transfer of data up to 32 kbytes. Type: Medium-sensitivity models.
Sensed current: 500 mA/1,000 mA(switchable).
Type: High-speed models.
Operating time: Less than 0.1 s.
Economical, Compact, High-performance,
DIN 48 × 48-mm Ground Fault Relay for Low,
Voltages.
Performs continuous monitoring and detection of ground faults,
in low-voltage circuits due to the deterioration of insulation in,
electrical devices.
Higher reliability ensured with improved resistance to high-fre,
quency noise when used for inverter loads.
Ground Fault Relays and through-type ZCTs (zero-phase current,
transformers) are mutually compatible.
The through-type ZCTs are equipped with test terminals,
allowing operation tests for Ground Fault Relays to be performed withease. Product name: CJ2H CPU Units.
Specifications: I/O capacity/Mountable Units(Expansion Racks),
2,560 points/40 Units(3 Expansion Racks max.) ;
Program capacity, 50K steps; Data memory capacity,
160K words(DM: 32K words, EM: 32K words × 4 bank);
LD nstructio execution time, 0.016 μs.
Current consumption(A): 5V,0.42(See note.); 24v, --.
Standards: UC1, N, L, CE.
CJ2H for high speed, high capacity.
The CJ2H Series is ideal for advanced machine.
automation needs such as those required in image.
processing inspection of electrical components and,
high speed sorting on conveyors. Size: 96 x 96mm.
Control output 1: relay output.
Control output 2: relay output.
Auxiliary output: 4 points (auxiliary output 2, 1 common, auxiliary output 3, 4 public general).
Power supply voltage: AC/DC24V.
Terminal shape: screw terminal table type.
Input category: full range multi input.
Heating wire break, SSR fault detection function: 1 points.
Communication: RS-485.
Event input: 2 points.
Remote SP input: -.
Transfer output: -.
Large screen display white PV legible. From selection to setting and operation are simple and easy to use.
Full capacity, function and performance of I/O. Suitable for more applications.
E5AC white LCDPV display height is about 25mm.
The upper panel and the front panel are equipped with tool ports.
With the communication conversion line (sold separately) connected to the computer to establish the controller without the need to install the wire for power supply.
Easy to install CX-Thermo (sold separately).
50ms high speed sampling period.
Model can be equipped with up to 4 point auxiliary output, 6 point event input,
1 point transfer output and remote SP input, suitable for a wide range of applications.
The main body is short, the thickness is only 60mm.
Easy to use programmable logic controller (PLC) is connected to the programmable logic controller (PLC).
The temperature controller is connected to each other by using the component communication.
A new type of proportional control allows you to control the valve.
F3WN-X0922N25 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=F3WN-X0922N25&select=5