C500-OA I/O Unit Triac Output 32 pts C500-OA225.
AC250V 1A.Direction of Operation Key insertion: Horizontal.
Cable length: 1 m.
2NC/1NO (Slow-action).
Slim Safety Door Switches with IP67 Rating.
Slim design with a width of only 17 mm.
(three-contact models).
Reversible design allowing either front or rear mounting.
Built-in Switches with two- or three-terminal contact.
construction are available
F3ZN-S0315N15
Operation Key with rubber mounting hole to absorb vibration and shock.
IP67 degree of protection. Power supply voltage: 100 to 240 VAC.
Heater control method: Phase control Cyclic control.
Input specifications: Two current inputs,
(for either single phase or threephase).
Output specifications: One relay output.
Communications output: RS-485.
Current input range: 2.00 to 22.00 A.
A high-precision Heater Element.
Burnout Detector compatible with a,
wide-range of heater control methods.
Push-in terminals reduce the workload.
Scaling.
NPN or PNP equivalent output.
Lineup includes models compatible with many heater control methods,
including ON/OFF control, phase control, and cyclic control.
High-precision heater burnout alarm with digital measurement.
Contributes to preventative maintenance.
If the gate function is disabled, the gate input can be used as an,
undercurrent/overcurrent relay or for motor or lamp loads.
Undercurrent detection values can be set separately for CT1 and CT2.
CE marking and cUL certified (K8AC-H2@@@). Sensor type: Through-beam.
Sensing distance: 15 m.
Connection method: M12 connector.
Model: NPN output.
A new generation in sensing performance.
Simplicity.
Simple selection.
Simple installation.
One family for all.
All standard applications covered.
A wide variety of models.
Models designed for special applications.
Non-stop detection.
High quality and reliability.
High EMC protection.
High light immunity.
Robust and waterproof housing. No. of steps: 6.
Rated voltage: 24 VDC, 100 VAC, 200 VAC.
Ideal for Controlling Pumps and Production.
Lines with Six or Twelve Stepping Circuits.
Built-in relays switch 2 A at 250 VAC or 30 VDC.
Initialization of stepping with reset input.
Uses memory that stores setting status for 10 days without.
power. All internal contacts are released when no power is supplied.
Detects an internal element malfunction caused by external.
noise, indicates the malfunction with an alarm indicator, and,
turns the relay alarm output ON. (An internal relay malfunction,
or internal relay contact weld cannot be detected.).
With safety-design terminals which prevent electric shock accidents.
With easy-to-see indicators which display the stepping status.
F3ZN-S0315N15 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=F3ZN-S0315N15&select=5