Appearance: Standard.
Sensing method: Through beam type (with slot).
Connecting method: Connector model (4 poles).
Sensing distance: 5 mm (slot width).
Operating mode: Dark-ON/Light-ON (2 outputs).
Indicator mode: Incident light.
Model: PNP output.
Built-in connector enables,
downsizing and easier connection.
Protective circuit for safe operation.
A built-in connector minimizes the shape and dimensional,
requirements
F3ZN-S0702N09
Two outputs: light-ON and dark-ON.
Complete lineup including seven different shapes.
Safer operation with built-in power supply reverse polarity,
protection.
Output overcurrent protection with a thermal shutdown,
circuit (patent pending).
The indicator can be seen from many directions to enable,
installation in more locations.
Connector with lock that mates with commercially available,
connectors. Type: Welding / wire type, M3 screw mounting.
Drive rod: R blade Shibai rod type.
Terminal specification: welding.
Contact specifications: 1c.
The minimum size of the long stroke type can be reliably switch
The body part size is 78% of the previous generation product, which is beneficial to the miniaturization of the equipment.
No swing bars are also used for easy long stroke specifications (OT reference value: 1.4mm).
Without harmful substances to the environment, the lead type has also been lead-free. Size: 48 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 2 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output 1: current output.
Control output 2: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event entry point: 2.
Transfer output: output (using control output).
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which can display the current value / target / operation.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation.
F3ZN-S0702N09 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=F3ZN-S0702N09&select=5