Control power supply voltage: 200/220 VAC.
Input: DC, Input voltage range, 0.2 to 12 V.
Overvoltage/Undervoltage Monitoring.
Relay for AC and DC Input.
Detect overvoltages or undervoltages (switch select,
able) from 4 mV to 300 V.
Detect undercurrent, reverse current, or overcurrent in,
DC circuits using shunt (SDV-FL).
Detect three-phase AC current for under and/or overcur,
rent using current converter
F3ZN-S0840P15
Available in 7 supply voltage configurations.
Single-function model with ON-delay, OFF-delay, or star,
tup lock settings (SDV-FH@T).
Select either AC or DC voltage input.
Polarity can be specified (SDV-FL) to enable easy re,
verse current detection.
Selectable reset value range from 2% to 30% of operat,
ing value (SDV-F).
LED operation indicator.
UL/CSA approval (SDV-F@). Type: screw terminal type, general type without cable.
Rated current; 5A AC125V.
Drive rod: sealing plunger type.
Terminal: screw terminal without cable.
Action indicator: no operation indicator.
Compared with D4E performance is stronger, in compliance with the requirements of high durability, high sealing.
Horizontal spring, with improved swing lever ratio of the built-in switch to provide a smooth action effect and a longer period of use.
Protection cover protects built-in switch from dust and oil pollution damage.
The plunger type combined with the solid sealing cover has longer service life.
One touch off connector wiring operation miscellaneous,
And reduce the downtime due to wiring and maintenance.
Gold Plated minimum load type is an ideal choice for electronic control.
Can provide terminal type plastic screw terminal system and terminal type plastic with operation indicator.
Certified by EN, UL, CSA and CCC (China Standard) standard.
Install the pitch and with the characteristics of D4E- - N and D4E. Number of beams: 48.
Protective height: 960mm.
Safety Light Curtains with Durable,
Impact-resistant Body and Long,
20-m Sensing Distance.
MS/MSF4800A Advanced Series.
Programming and Diagnostics Module (PDM) makes it easy,
to set functions.
Series connection is possible only with the MSF4800A.
Blanking can be set.
Muting is possible only with the MSF4800A by using the,
MS4800-RM6 Resource Module.
MS/MSF4800B Basic Series,
Features all necessary basic Safety Light Curtain functions.
Series connection is possible only with the MSF4800B.
Programming and Diagnostics Module (PDM) makes it easy,
to set functions.