Actuator: One-way roller arm lever (horizontal).
Conduit size: 1-conduit; Pg13.5.
Built-in switch mechanism: 2NC(Snap-action).
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms.
(Slow-action models with MBB contacts are available.)
M12-connector models are also available, saving on labor and,
simplifying replacement
G2E-134P-M-US DC5
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only).
Certified standards: UL, EN (TÜV), and CCC. Size: 48 x 48mm.
Control output 1: relay output.
Control output 2:--.
Auxiliary output: 2 independent points.
Power supply voltage: AC100 ~ 240V.
Terminal type: screw terminal table type.
Input category: full range multi input.
Heater break, SSR fault detection function: -.
Communication: RS-485.
Event input: 1 points.
Remote SP input: -.
Transfer output: -.
Using large font PV display (white), improve visibility.
Selection, operation and setting.
Functional performance of input and output points.
Support for more extensive range of applications.
Using high PV 15.2mm display (white), improve visibility.
High speed sampling to achieve 50ms.
With auxiliary output (maximum 3 points), event input (maximum 4 points), the transmission output,
Remote SP input function, support for a variety of applications.
E5CC 60mm has a depth of slender body.
The use of communication adapter cable (sold separately) connected with a computer.
After that, no power supply connection can be set.
It can be easily set by CX-Thermo (sold separately).
Easy to connect with PLC through no program communication.
Combined temperature control device through component communication. Unit type: CS1 Special I/O Units.
Product name: Isolated-type DC Input Unit.
Input points : 4 inputs.
Signal range: 4 to 20 mA, 0 to 20 mA,
0 to 10 V, ±10 V, 0 to 5 V, ±5 V,
1 to 5 V, 0 to 1.25 V, ±1.25 V.
Conversion speed (resolution):
20 ms/4 inputs, 10 ms/2 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.12A; 26V, 0.12A.
Standards: UC1, N, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and space compared,
with previous systems.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCUs,
to construct complete process control systems.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.