LK Automation Limited LK Automation Limited
Brand Sort: OMRON
Home >> Price
G3MB-202PL-UTU-MS DC12 Pirce
No PHOTO
OMRON G3MB-202PL-UTU-MS DC12
Output: DPDT.
Lighting: Non-lighted.
Pushbutton colorsymbol: R: red, Y: yellow; PY: pure yellow
G: green, A: blue; PW: pure white; B: black *2.
Item: Momentary operation (Self-resetting).
Separate Construction with.
Cylindrical 16-dia. Body.
Miniature design of 28.5 mm, the smallest class in the industry.
Detachable Switch.
The same contacts can be used for both standard loads and microloads G3MB-202PL-UTU-MS DC12
Easy-to-wire terminal arrangement.
Certified for EN 60947-5-1. Output: SPDT.
Lighting: LED.
Operating voltage: 12 VAC/VDC.
Pushbutton colorsymbol: R: red, Y: yellow; PY: pure yellow
G: green, A: blue; W: white; B: black *2.
Item: Momentary operation (Self-resetting).
Separate Construction with.
Cylindrical 16-dia. Body.
Miniature design of 28.5 mm, the smallest class in the industry.
Detachable Switch.
The same contacts can be used for both standard loads and microloads.
Easy-to-wire terminal arrangement.
Certified for EN 60947-5-1. Appearance: Square/Projection type LED voltage-reduction lighting,
(with Voltage Reduction Unit) A22L-D.
Output: SPST-NC.
Lighting: LED.
Operating voltage: 100 VAC.
Operation: Alternate operation (self-holding).
Illumination color: R (red); Y (yellow); G (green); W (white); A (blue).
Install in 22-dia. or 25-dia. Panel Cutout.
(When Using a Ring).
Lever for easily mounting and removing the Switch Unit.
Increase wiring efficiency with three-row mounting of Switch Blocks.
Finger protection mechanism on Switch Unit provided as a standard feature.
Use 25-dia. ring to install in 25-dia. panel cutouts.
Mounted using either open-type (fork-type) or closed-type.
(round-type) crimp terminals.
IP65 oil resistance (non-lighted models).
IP65 (lighted models). E5CN, E5EN, E5AN, E5ZN, E5 / R software.
Can shorten the parameter setting, equipment adjustment, maintenance time.
Can use the computer to compile, edit and download all parameters.
Can reduce the parameter setting time.
Online monitoring function.
Up to 31 simultaneous monitoring of the data.
(but only in the same series of thermostat).
Function of parameter mask (not showing the parameters that are not used).
(E5_N, E5_R)
With CX-Programmer at the same time start and use,
Can share the folder used by CX-Programmer.
The function of the model can be automatically retrieved only by the unit number,
Trend monitoring connection function (automatic inspection function).
G3MB-202PL-UTU-MS DC12 Operation manual/Instructions/Model selection sample download link: /searchDownload.html?Search=G3MB-202PL-UTU-MS DC12&select=5


...more relevant model market price >>>>
Related products