Size: 48 x 96mm.
Category: power AC100 ~ 240V with.
Shell color: black.
Control output 1: output unit mode.
Control output 2: output unit mode.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase or three phase heater detection function.
Event entry point: 2.
Transfer output: transfer output (special terminal).
Remote SP:4 to 20mA input
G3NA-220B AC100-120
Communication: RS-232C.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm), interactive display PV/SV.
Through the support software (Ver.4.3 CX-Thermo) makes the process of setting management becomes very
Simple use of simple computing functions (AND/OR logic and delay) to set the implementation of flexible contact output.
Through the infrared port can be carried out from the front of the communication.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller. Control cycle: Yearly.
Number of outputs: 2 circuits.
Mounting method: Flush mounting.
Supply voltage: 24 VDC.
Easier, More Convenient Time Switches, with,
New 4-circuit Output and Yearly Models in,
Addition to 2-circuit Weekly Models.
Independent Day Keys provide easier operation.
Temporary holiday setting function makes it easy to turn OFF,
output for holidays and non-operating days.
Settings can be made even with the Time Switch turned OFF.
Test mode enables easy program checking.
Complies with EMC Directives, UL/CSA, and other safety standards.
Includes summer time (DST) adjustment.
Yearly models also offer automatic switching to DST.
Set value can be changed both upward and downward for speedier setting.
Integrated temperature compensation circuit helps keep,
accurate time over a wide temperature range. (See note 1.)
Includes time counter and total counter functions with alarm,
indicator. (See note 2.)
Bank function allows program switching by an external input.
(See note 3.)
New 4-circuit output models with a compact, 72 × 72-mm DIN,
size added to the series.
G3NA-220B AC100-120 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=G3NA-220B AC100-120&select=5