Actuator: Roller lever: R38.
Item: Basic.
Connector shape: Threaded (M12).
Built-in switch type: Airtight.
Voltage: DC.
Wiring locations: NC + NO 4 core.
Connector pin No: NC 1 2; NO 3 4.
Select the Best Two-circuit Switch for the,
Operating Environment and Application,
from a Wide Range of Models,
A wide selection of models is available, including General-purpose,
Environment-resistant, and Spatter prevention Switches
D3V-165M-2C5
Standard-feature gold-clad crossbar contacts provide high reliability.
Applicable to either standard loads or microloads.
Switches with Lever Actuators provide 90° overtravel,
one-side operation, and four-direction head mounting.
Approved standards: EN/IEC, UL, cUL, and CCC.
Contact your OMRON representative for information on approved models. Actuator: Roller lever (resin lever, resin roller).
Conduit size: 2-conduit; M20.
Built-in switch mechanism: 2NC(Snap-action).
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms.
(Slow-action models with MBB contacts are available.)
M12-connector models are also available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only).
Certified standards: UL, EN (TÜV), and CCC. Cable length L: 3.0 m.
Connect Connector-Terminal,
Block Conversion Units (XW2@) to,
I/O Units for Programmable,
Controllers with one touch. Ratings: Standard load; 5 A at 125 VAC.
Cable: VCTF cable *2.
Actuator: Pin plunger.
Cable length : 3 m.
Compact Limit Switch That''s Also.
Thin and Highly Sealed.
Approved by EN, UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved models.)
Sealing characteristics that meet IEC IP67 degree of protection.
Triple-sealed construction:
Plunger section sealed via nitrile rubber packing seal and,
diaphragm; switch section sealed via nitrile rubber cap;
cable entrance sealed via encapsulating material.
Cable lengths of 3 and 5 m available on standard models.
Models also available with UL and CSA-certified cables.
Multiple mounting possible with Switches with Plungers.
Models with red LED indicators added to series for easy,
confirmation of operation.
(Set by default to light for non-operation.)
VCTF oil-resistant cables with CE marking.
(Applicable only to standard models.)
D3V-165M-2C5 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=D3V-165M-2C5&select=5