LK Automation Limited LK Automation Limited
Brand Sort: OMRON
Home >> Price
D4C-4524 Pirce
  • Brand: OMRON
  • Country: JAPAN
  • Name: Enclosed Switch
  • Model: D4C-4524
  • Price: U.S.$ 120.62
next one: OMRON D4C-5232
Last one: OMRON D4C-4502
OMRON D4C-4524
Isolation: Photocoupler.
Zero cross function: Yes.
Indicator: Yes.
Rated output load: 3 A at 100 to 240 VAC (See note 1.).
Rated input voltage: 5 to 24 VDC.
International Standards for G3F Series,
Same Profile as MY Power Relays.
Shape-compatible with mechanical relays.
Certified by UL, CSA, and VDE (model numbers with a suffix of“-VD”).
Socket type, same size as MY Power Relays.
Operation indicator provided to confirm input D4C-4524
(model numbers with “N” before the suffix). Material: N10276 (See note).
Weight (g): Approx. 190.
Material indication lines: 4 lines.
A Wide Variety of Electrodes for Long Lasting.
Reliability.
Standard Electrodes are made of stainless steel (SUS 304) and,
can be used in applications for purified water.
SUS316 Electrodes can be used in applications where resistance,
to corrosion is required. Titanium and HAS Electrodes can be,
used in applications where resistance to acid is required.
For applications where long electrodes are required, a connection,
nut and two Lock Nuts can be used to extend the electrodes 1 m,
at a time. Time specification: Instantaneous type.
Current setting range: 50 to 160 A.
Operating voltage: 400/440 VAC.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM.
D4C-4524 Operation manual/Instructions/Model selection sample download link: /searchDownload.html?Search=D4C-4524&select=5


...more relevant model market price >>>>
Related products
OMRON
Enclosed Switch
D4C-3233
OMRON Enclosed Switch D4C-3233
Ratings: Standard load 4 A at 30 VDC.
OMRON
Enclosed Switch
D4C-1450
OMRON Enclosed Switch D4C-1450
Ratings: Standard load 5 A at 250 VAC,
OMRON
Enclosed Switch
D4C-1220-P
OMRON Enclosed Switch D4C-1220-P
Operation indicator: Without operating i
OMRON
Enclosed Switch
D4C-1560
OMRON Enclosed Switch D4C-1560
Ratings: Standard load 5 A at 250 VAC,