Output: SPDT.
Lighting: Non-lighted.
Pushbutton colorsymbol: R: red, Y: yellow; PY: pure yellow
G: green, A: blue; W: white; PW: pure white.
Item: Momentary operation (Self-resetting).
Separate Construction with.
Cylindrical 16-dia. Body.
Miniature design of 28.5 mm, the smallest class in the industry.
Detachable Switch.
The same contacts can be used for both standard loads and microloads
D4GL-1BFG-A
Easy-to-wire terminal arrangement.
Certified for EN 60947-5-1. Terminal type: Exposed-lead Models.
Protective tubing diameter D (mm): 3.2 dia.
Protective tubing length L: 15cm.
Lead wire type: Standard.
Lead wire length M : 2m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Appearance: 6.5 dia.
Sensing distance: 2 mm.
Connecting method: Pre-wired Models (2 m).
Cable specifications: PVC (oil-resistant).
Operation mode: NO.
Wire color /pin arrangement: Brown: +V, Black: Output, Blue: 0 V.
Model: NPN output.
Ultra small size, but surprisingly easy installation!
With the addition of M4, 5.4-dia., 6.5-dia. size, unshielded,
pre-wired connector model, and connector model, a total of,
108 model variations are available.
High-speed response frequency stably detects moving,
objects: 5 kHz max.
Four indicator lamps for easier indicator positioning.
Special mounting brackets reduce time and efforts for,
installation.
Protective Stainless-steel Spiral Tube against wire,
breakage is available (M4, M5 only).
Models also available with standard cables that are 5 m long,
or with robot (bending-resistant) cables. Size: 48 x 96mm.
Type: power AC/DC24V with.
Shell color: black.
Control output 1: output unit mode.
Control output 2: output unit mode.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase or three phase heater detection function.
Event entry point: 2.
Transfer output: -.
Remote SP:4 to 20mA input.
Communication: RS-422.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm), interactive display PV/SV.
Through the support software (Ver.4.3 CX-Thermo) makes the process of setting management becomes very
Simple use of simple computing functions (AND/OR logic and delay) to set the implementation of flexible contact output.
Through the infrared port can be carried out from the front of the communication.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller.
D4GL-1BFG-A Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=D4GL-1BFG-A&select=5