LK Automation Limited LK Automation Limited
Brand Sort: OMRON
Home >> Price
D4JL-1PFA-C5 Pirce
No PHOTO
OMRON D4JL-1PFA-C5
Continuation of the E6B2 high cost, value also have more choice.
E6B3, E6C4 blockbuster debut! Complementary output of the first starting high anti interference.
40mm diameter, shaft diameter of phi 8mm universal, with strong axial load capacity.
50mm diameter, shaft diameter of phi 10mm rugged, with strong axial load capacity,
At the same time, the use of IP65 anti drip, anti oil structure.
E6B2 complementary output will be issued over the same period D4JL-1PFA-C5
Connection length to reach a full 30m! Classification: Relay with Auxiliary Contact Block.
Structure: 4 poles + 2 poles.
Contact configuration: Relay, 3PST-NO/SPST-NC; Auxiliary Contact Block, DPST-NC.
Rated Voltage: 12, 24 VDC.
Compact Electromagnetic Contactors That.
Switch 40 A at 440 VAC.
One pole carries 40 A.
UL 508 and UL 840 NC contacts (resistive 40 A 480 VAC, 60 Hz, 80,000 operations).
EN 60947-4-1 NC contacts (AC1 40 A 440 VAC, 50/60 Hz, 80,000 operations).
Ideal for supply power to industrial inverters, servo drivers, and other devices,
and switching power to motors and other equipment.
The maximum load capacity of 160 A when using 4-pole parallel connections.
EN 60947-4-1 certification for mirror contact mechanism obtained by combining,
the Relay with an Auxiliary Contact Block.
Conforms to European PV standard (VDE0126).
Approx. 30% less operation noise than a standard electromagnetic contactor.
(Approx. 100 dB reduced to approx. 70 dB.)
Approx. 50% the volume of a standard electromagnetic contactor,
to help downsize control panels.
According to OMRON investigation of IIEC-AC1 50 A specifications. Power ratings: 90 W.
Input voltage: 100 to 240 VAC(allowable range: 85 to 264 VAC or 80 to 370 VDC)*1.
Output voltage: 24 V.
Output current: 3.75 A.
Alarm output *2: Sourcing.
UL Class 2 Output standards: Yes.
Model number(screwless terminal block).
60/90/120/180/240/480-W Models.
New Models with Indication.
Monitor and Simple Functions for.
Easy System Commissioning.
New 90-W models with indication monitor that.
conform to UL Class 2 Output standards.
New models with screwless terminal blocks and,
indication monitor.
Status displayed on 3-digit, 7-segment display.
Safety standards: UL 508/60950-1,
CSA C22.2 No. 107.1/60950-1,
EN 50178 (= VDE 0160), EN 60950-1 (= VDE 0805 Teil 1).
Input conditions: DC input is also possible from 80 to 370 VDC.
(Not compliant with EC Directives and other safety standards.)
D4JL-1PFA-C5 Operation manual/Instructions/Model selection sample download link: /searchDownload.html?Search=D4JL-1PFA-C5&select=5


...more relevant model market price >>>>
Related products