Appearance: Square/Projection type LED lighting,
(without Voltage Reduction Unit) A22L-D.
Output: SPST-NC + SPST-NC.
Lighting: LED.
Operating voltage: 24 VAC/VDC.
Operation: Momentary operation (self-resetting).
Illumination color: R (red); Y (yellow); G (green); W (white); A (blue).
Install in 22-dia. or 25-dia. Panel Cutout.
(When Using a Ring).
Lever for easily mounting and removing the Switch Unit
D4N-2B72R
Increase wiring efficiency with three-row mounting of Switch Blocks.
Finger protection mechanism on Switch Unit provided as a standard feature.
Use 25-dia. ring to install in 25-dia. panel cutouts.
Mounted using either open-type (fork-type) or closed-type.
(round-type) crimp terminals.
IP65 oil resistance (non-lighted models).
IP65 (lighted models). Unit classifi cation: CS1 CPU Bus Unit.
Product name:Controller Link Unit.
Specifications: Communications cable,
Optical ring H-PCF cable;
Communications type, Data links and,
message service; Duplex support,
Yes. Unit duplexing and cable loop,
back are supported.
Max. Units mountable per CPU Unit,
Non-duplex: 8, Duplex: 11 (6 Units,
comprising 3 sets of Duplex Units,
+ 5 Non-duplex Units).
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.52A; 26V, --.
Standards: UC1, N, L, CE.
New Controller Link Units,
Now with 4,000 Send Words.
The Controller Link is an,
FA network that can send,
and receive large amounts,
of data easily and at high speed.
The Controller Link supports data,
links that enable sharing data between,
PLCs and computers and a message service,
that enables sending and receiving,
data whenever required.
With Wired Controller Link Units,
systems can be flexibly built by using,
Repeater Units to enable T branches,
long-distance wiring, and converting,
part of the network to optical cable. Ontology: terminal type, analog input type.
Category: control output 2 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output 1: relay output.
Control output 2: voltage output (SSR driver)
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event entry point: 2.
Transfer output: -.
Communication: -.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Further performance improvement.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
D4N-2B72R Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=D4N-2B72R&select=5