Type: 1-Conduit.
Contact configuration: Slow-action; 2NC/1NO.
Conduit opening/Connector: M20.
Multi-contact, Labor-saving,
Environment-friendly, Next,
generation Safety-door Switch.
Lineup includes three contact models with 2NC/1NO,
and 3NC contact forms and MBB models in addition,
to the previous contact forms 1NC/1NO, and 2NC.
M12-connector models are available, saving on,
labor and simplifying replacement
D4SL-4KDG-D4N
Standardized gold-clad contacts provide high,
contact reliability.
Applicable to both standard loads and microloads.
Variety of metallic heads available. Output: DPDT.
Lighting: Non-lighted.
Pushbutton colorsymbol: R: red, Y: yellow; PY: pure yellow
G: green, A: blue; W: white; Non-lighted.
Item: Alternate operation (Self-holding).
Separate Construction with.
Cylindrical 16-dia. Body.
Miniature design of 28.5 mm, the smallest class in the industry.
Detachable Switch.
The same contacts can be used for both standard loads and microloads.
Easy-to-wire terminal arrangement.
Certified for EN 60947-5-1. Unit: Connector model.
I/O classification: Digital output.
Internal I/O common: PNP (+ common).
I/O points: 16.
I/O connections: Molex connector.
Power supplyvoltage: 24 VDC.
I/O specification: 0.5 A, DC/transistor.
Digital I/O Units Compatible with MULTIPLE I/O TERMINAL,
Terminal block, connector, and high-density connector,
models are available.
The circuit block of the terminal block model can be,
mounted or dismounted for ease of maintenance without,
disconnecting the wires.
DIN track mounting. A New High-performance Controller: High Resolution, High Speed,
and High Input Accuracy.
Logic Operations and Preventive.
Maintenance Function.
High-resolution display with 5 digits/0.01°C display in a compact,
Controller (48 x 48 mm).
High-speed sampling cycle of 60 ms.
High Accuracy,
Thermocouple/Pt input: ±0.1% of PV,
Analog input: ±0.1% FS,
Universal inputs on all models (thermocouple, PT, or analog,
input) to handle various sensors with one Controller.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV.
Flexible contact outputs with logic operations (AND, OR, and,
delays) set from the Support Software (CX-Thermo Ver. 4.0),
Preventive maintenance for relays in the Temperature.
Controller using a Control Output ON/OFF Counter.
D4SL-4KDG-D4N Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=D4SL-4KDG-D4N&select=5