Type: 1-conduit.
Mounting direction: Front-side mounting.
Conduit size: G1/2.
1NC/1NO (Slow-action).
The Special Operation Key Activates a Direct.
Opening Mechanism to Open the Contacts.
and Shut Off Control Circuits when Protective.
Doors Are Opened on Machine Tools or Other.
Equipment.
Conforms to EN (TÜV) standards corresponding to the CE marking.
Certified by UL and CSA standards.
The Switch contact is opened by a direct opening mechanism,
(NC contacts only) when the protective cover is opened
D4SL-N3HFG-DN The EN-certified.
direct opening mechanism is indicated by on the Switch.
Malfunctions and false operation prevented by special Operation Key.
Wide temperature range specifications: −40 to 80°C.
Degree of protection of the switch box: IP67 (EN60947-5-1). Unit type: CJ1 Basic I/O Units.
name: B7A Interface Units.
Specifications: I/O points, 64 inputs;
External connection, Removable terminal block.
No. of words allocated: 4 words.
Current consumption: 5V, 0.07A; 24V, --.
Standards: UC1, CE.
It transmits 16 points of I/O signals per,
word with a pair of cables.
Easy and minimized wiring effort,
The B7A Interface Unit and B7A Link Terminal,
can be used in the same way as a standard,
Basic I/O Unit and I/O Terminal without,
any need to worry about communications.
This characteristic reduces the wiring,
when using more than one relatively remote,
sensor or actuator. Power supply voltage: 5 VDC.
Output configuration: Voltage output.
Resolution (pulses/rotation): 1,000; 2,000; 3,600; 5,000; 6,000.
High-resolution Encoder.
Incremental model.
External diameter of 55 mm.
Resolution of up to 6,000 ppr. Case color: Black.
Lighting method: LED; 24 VDC.
Display color symbol: R.O.G.W.
Large Rectangular-bodied Indicators.
Excellent illumination with even surface brightness.
Three-color models (green, orange, red; chameleon lighting),
included in lineup. Number of beams: 40.
Protective height: 800mm.
Safety Light Curtains with Durable,
Impact-resistant Body and Long,
20-m Sensing Distance.
MS/MSF4800A Advanced Series.
Programming and Diagnostics Module (PDM) makes it easy,
to set functions.
Series connection is possible only with the MSF4800A.
Blanking can be set.
Muting is possible only with the MSF4800A by using the,
MS4800-RM6 Resource Module.
MS/MSF4800B Basic Series,
Features all necessary basic Safety Light Curtain functions.
Series connection is possible only with the MSF4800B.
Programming and Diagnostics Module (PDM) makes it easy,
to set functions.
D4SL-N3HFG-DN Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=D4SL-N3HFG-DN&select=5