Actuator: Roller lever (resin lever, resin roller).
Conduit size: 1-conduit; M12 connector.
Built-in switch mechanism: 2NC(Snap-action).
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms.
(Slow-action models with MBB contacts are available.)
M12-connector models are also available, saving on labor and,
simplifying replacement
E2E-X10Y2-53 5M
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only).
Certified standards: UL, EN (TÜV), and CCC. I/O classification: Digital input.
Internal I/O circuit common: NPN (+ common).
I/O points: 8.
I/O connection method: Sensor connector.
Compact Remote I/O Terminals that.
Save Wiring Effort and Enable.
Long-distance Communications.
Long-distance or high-speed communications,
mode is selectable.
Incorporates I/O connectors making it possible to,
minimize the size.
I/O connectors save wiring effort.
Flexible DIN track mounting is possible through a,
DIN track attachment.
Eight-point sensor connector models and 16-point,
MIL connector models are the same size. Size: 48 x 24mm.
Control output 1: relay output.
Control output 2:--.
Auxiliary output: 2 points.
Power supply voltage: AC/DC24V.
Terminal type: screw terminal table type (with terminal cover).
Input category: full range multi input.
Heater break, SSR fault detection function: -.
Communication: RS-485.
Event input: -.
A small body of 48 * 24mm specifications on the condensation operation, E5_C series of high performance.
Slender body width 48mm * 24mm * 90mm high depth,
The most suitable for small devices / physical and chemical equipment, etc..
Although the small size, but also through the character of the high 10.5mm white PV display to achieve high recognition.
The terminal stage is adopted to disassemble and assemble the structure, which improves the maintenance performance.
The connection method can be selected from a screw terminal and a PUSH-IN fastening terminal.
High speed sampling of 50ms is realized.
Easy to connect with PLC through no program communication.
The use of electric communication conversion Village (sold separately) connected to the computer after,
No power connection can be set.
It can be easily set by CS-Thermo (sold separately).
E2E-X10Y2-53 5M Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=E2E-X10Y2-53 5M&select=5