Contact type: Standard load (250 VAC, 2 A; 125 VDC 0.4 A).
Operation: Momentary operation (Self-resetting).
Output: DPDT.
Lighting: Incandescent lamp, 28 VAC/VDC.
Operation Unit color symbol: Enter the desired color symbol for the Pushbutton
n @. R (Red); Y (Yellow); G (Green); A (Blue); W (White).
Pushbutton Switch Series with.
Square 40-mm Body.
Combines miniature design with distinct but soft sense of operation
E2E-X7D1-M1GJ-T-Z 0.3M
Easy panel mounting from the front and simple lamp replacement.
without tools. Round Water-resistive Smartclick.
Connectors That Reduce Installation Work.
A newly developed lock mechanism that is compatible with round M12 connectors.
Simply insert the Connectors, then turn them approximately 1/8 of a turn to lock.
A positive click indicates locking.
Features the same degree of protection (IP67) as M12 connectors.
A full line-up of models is planned.
Connectors with Cables are UL approved. E32-T25XR type: standard type; soft (new standard),
Specialty: flat shape (small),
Shape / detection distance (mm): 160; 130; 75 (30),
Standard test object
(minimum test object) (mm) 1: 0.5 (0.005),
Fiber element for meeting diversified needsControl output 1: Relay output.
Control output 2: Relay output.
Auxiliary output: Two.
Communications: RS-485.
Heater burnout: One.
Event inputs: Two.
Power supply voltage: 100 to 240 VAC.
Large White PV Display That’s Easier to Read.
Easy to Use, from Model Selection to Setup and Operation.
A Complete Range of I/O Capacities,
Functions, and Performance.
Handles More Applications.
The white PV display with a height of 15.2 mm improves visibility.
High-speed sampling at 50 ms.
Short body with depth of only 60 mm.
Easy connections to a PLC with programless communications.
Use component communications to link Temperature,
Controllers to each other. Type: H5CX-A series.
Time specifications: 0.001 to 9.999 s, 0.01 to 99.99 s,
0.1 to 999.9 s, 1 to 9999 s, 1 s to 99 min 59 s, 0.1 to 999.9 min,
1 to 9999 min, 1 min to 99 h 59 min, 0.1 to 999.9 h, 1 to 9999 h.
Operating modes: Timer Mode, A: Signal ON Delay I, A-1: Signal ON Delay II,
A-2: Power ON Delay I, A-3: Power ON Delay II, b: Repeat cycle 1,
b-1: Repeat cycle 2, d: Signal OFF Delay, E: Interval, F: Cumulative,
Z: ON/OFF-duty-adjustable flicker, S: Stopwatch, Twin Timer Mode,
toff: Flicker OFF Start 1, ton: Flicker ON Start 1,
toff-1: Flicker OFF Start 2, ton-1: Flicker ON Start 2.
External connections: Screw terminals.
Input: Signal, Reset, Gate (NPN/PNP input).
Output: Contact output (time-limit SPDT).
Supply voltage: 12 to 24 VDC/24 VAC.
The Timer with the Shortest Body,
in the Industry.
E2E-X7D1-M1GJ-T-Z 0.3M Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=E2E-X7D1-M1GJ-T-Z 0.3M&select=5