Type: output module.
Insulation: photo coupler.
Zero crossing function.
Action display light: No.
Output rated voltage: AC100 3A ~ 240V.
Input rated voltage: DC4 ~ 24V.
Logic circuit and load interface.
I/O solid state relay.
With the input module (AC, DC), the output module (AC, DC).
Product series, the color of each module to distinguish.
You can confirm the action of SSR by using the action display light
E2EV-X2C2 2M
Between input and output voltage 4000V. Insulation method: Photocoupler.
Operation indicator: Yes (yellow).
Zero cross function: No.
Applicable output load: 75 A, 180 to 480 VAC.
Rated input voltage: 5 to 24 VDC.
High-power, Load-control SSRs with.
High Current of 75 or 150 A and High.
Voltage of 240 or 480 VAC.
RoHS compliant.
Models also available with no zero cross.
Replaceable power elements.
Conforms to cULus standards and EN standards (TÜV certification). Actuator: Adjustable roller lever, form lock (metal lever, rubber roller).
Conduit size: 1-conduit; Pg13.5.
Built-in switch mechanism: 2NC (Slow-action).
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms.
(Slow-action models with MBB contacts are available.)
M12-connector models are also available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only).
Certified standards: UL, EN (TÜV), and CCC. Power supply voltage: 100 to 240 VAC.
Type: Temperature input.
Output relays: 1 relay.
Input types: Thermocouple or platinum resistance thermometer.
Setting units (setting range): Setting unit: 1°C or 1°F (0 to 999°C/°F).
Compact and Slim Relay Ideal for.
Temperature Alarms and Monitoring.
Excessive temperature increases can be prevented and,
abnormal temperatures can be monitored.
Temperature monitoring in slim design with a width of just 22.5 mm.
Rotary switches simplifies temperature settings.
Universal-input support for thermocouple or platinum,
resistance thermometer sensor input.
Change the output relay between normally open and,
normally closed operation.
Alarm status identification with LED indicator.
Self-holding output.
Alarm output status can be retained even if the power,
supply is turned OFF.
E2EV-X2C2 2M Operation manual/Instructions/Model selection sample download link: