Long-distance Photoelectric Sensor.
That Supports AC/DC Power Supplies.
Long sensing distance that is approximately 8,
times that of our conventional model (for the,
Through-beam and Diffuse-reflective models).
(Through-beam: 40 m, Retro-reflective: 7 m, and,
Diffuse-reflective: 2.5 m.) .
Improved visibility:
A red LED that makes the spot visible.
Large indicators that can be seen even from a,
distance
E2F-X5Y2 6M
Improved operability.
(Enlarged sensitivity adjuster and operation selector)
Freely selectable power supply input (24 to 240 VDC, 24 to 240 VAC).
(Additional types added to the DC type lineup.)
Models with infrared LEDs are also available. Appearance: Shielded, 8 dia.
Sensing distance: 2.5 mm.
Model: Output configuration, NPN open-collector output; NO.
Subminiature Sensors with.
Long-distance Detection.
Shielded Sensor Heads from 3-mm to M12 diameters that,
can be embedded in metal.
Robotics cables provided as a standard feature (DC 2-Wire Models).
Indicator provided in Amplifier cable for easy confirmation of operation.
Power supply range of 5 to 24 VDC for DC 3-Wire Models. Output: SPDT.
Lighting: LED.
Operating voltage: 12 VAC/VDC.
Pushbutton colorsymbol: R: red, Y: yellow; PY: pure yellow
G: green, A: blue; W: white; B: black *2.
Item: Momentary operation (Self-resetting).
Separate Construction with.
Cylindrical 16-dia. Body.
Miniature design of 28.5 mm, the smallest class in the industry.
Detachable Switch.
The same contacts can be used for both standard loads and microloads.
Easy-to-wire terminal arrangement.
Certified for EN 60947-5-1. Model: C200H-OC225.
No. of points: 16 pts.
Specifications: 2A, 250VAC/24VDC(For resistive loads).Count input: No-voltage.
Max. counting speed: 30 Hz ←→ 1 kHz(switchable).
Display: 7-segment LCD.
Model: Light-gray body.
Eight-digits, counting range 0 to 99999999.
Dual input speed: 30 Hz ←→ 1 kHz,
(except for AC/DC multivoltage input models). Unit classification: CJ1 Special I/O Units.
Product name: ProcessInput Units,
(Isolated-type Thermocouple Input Units).
Input points: 2 inputs.
Signal range selection:
Set separately for each input.
Signal range: Thermocouple:
B, E, J, K, L, N, R, S, T, U,
WRe5-26, PLII DC voltage: ±100 mV.
Conversion speed (resolution): Conversion,
speed: 10 ms/2 inputs, Resolution: 1/64,000.
Accuracy at ambient temperature of 25°C:
Standard accuracy: ±0.05% of F.S.
External connection: Removable terminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.18A; 24V, 0.06A.
Standards: UC1, CE.
A Single Unit Handling All Types of Inputs,
such as Temperature Sensor Inputs and,
Analog Signal Inputs (e.g., 4 to 20 mA or 1 to 5V).
A Unit supports four input channels,
each of which can be set to a
platinum resistance thermometer, thermocouple,
and DC signal (current, voltage).
All inputs are isolated.
E2F-X5Y2 6M Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=E2F-X5Y2 6M&select=5