E2FM-X1R5D1-M1GJ 0.3M Pirce
No PHOTO
OMRON E2FM-X1R5D1-M1GJ 0.3M
E32-D81R type: environment resistant; heat resistant,
Specialty: heat resistant: 200,
Bending radius (mm): R10.
Standard test object (minimum test object) (mm) 1: (0.005),
Fiber element for meeting diversified needsSetting range: 2 to 20 mA AC/DC, 10 to 100 mA AC/DC, 50 to 500 mA AC/DC.
Power supply voltage: 100 to 240 VAC.
Ideal for Current Monitoring for.
Industrial Facilities and Equipment.
Monitor for overcurrents and undercurrents simultaneously E2FM-X1R5D1-M1GJ 0.3M
Separate settings and outputs supported for overcurrents and undercurrents.
Use commercially available CTs (CT current on secondary,
side: 0 to 1 A or 0 to 5 A).
Manual resetting and automatically resetting supported by one Relay.
Startup lock and operating time can be set separately.
Two sets of SPDT output contacts, 5 A at 250 VAC (resistive load).
Output status can be monitored using LED indicator.
Inputs are isolated from the power supply. Appearance: ADR shell.
Circuit structure and open circuit mode: constant circuit contact, secondary current circuit breaker.
Rated current: AC5A.
Rated frequency: 50/60Hz (switching).
Current adjustment range: time limit elements: 3-3.5-4-4.5-5-6A, 6 shunt;
Instantaneous elements: 20-30-40-50-60A-, 6 shunt.
Action time: time limit elements: 0.25-0.5-1-2-3-4-5-6-7-8-9-10-15-30-60-120,
Minimum action value, adjust the scale of movement, 300% over current, 10s plus or minus 17%;
700% over current, 16.7s plus or minus 12%; instantaneous elements: 200% over current, 50ms.
Control power supply: do not.
Rated consumption VA:6VA.
Contact capacity: AC12V, 60A (CT secondary current) 100 times; AC20V, 100A (CT secondary current) 3 times.
Contact: AC250V, 5A, cos, DC30V, 5A, =1; Cos =1.
Automatic experiment: there.
Display: measurement display, resolution. Display resolution 9.9A the following is 0.1A, more than 1A.
Display range: 2.0A-20A, output display, trip (R phase and T phase) manual reset,
Instant manual reset type.
Excitation surge current suppression (fuzzy inference): the relative basic wave component second harmonic components of the containing rate is higher than 5%,
In the above area, the excitation surge current can be suppressed.
Quality: about 1.2kg.
External: Mount Searl N1.5.
Digital over current K2CA-H type,
Using the advanced technology of fuzzy inference to make the protection and coordination of digital DCR.
And automatic testing machine, so that the relay test is easy.
By using fuzzy inference, the excitation surge current is reduced.
Improve reliability by monitoring function at any time.