Shape: square.
Protection structure: IP40.
Action: alternate.
Operation Department color: red.
Column length 18mm, circular F8 series.
High brightness and with uniform light.
Round type easy opening.
Small and operation feel good. Number of beams: 80.
Protective height: 1600mm.
Safety Light Curtains with Durable,
Impact-resistant Body and Long,
20-m Sensing Distance.
MS/MSF4800A Advanced Series
E32-DC200F-S20
Programming and Diagnostics Module (PDM) makes it easy,
to set functions.
Series connection is possible only with the MSF4800A.
Blanking can be set.
Muting is possible only with the MSF4800A by using the,
MS4800-RM6 Resource Module.
MS/MSF4800B Basic Series,
Features all necessary basic Safety Light Curtain functions.
Series connection is possible only with the MSF4800B.
Programming and Diagnostics Module (PDM) makes it easy,
to set functions. Installation method: surface mount, embedded mounting (common).
Action: power on delay action.
Action mode / reset mode: time limit action / auto reset.
Set lock mechanism.
External connection mode: 8P socket.
Time limit contact: 1c.
Instantaneous contact: 1c.
1 timer to achieve AC/DC free power,
8 action functions 0.1 seconds to 9990 hours.
Through time display windows wide, eye-catching.
Free power mode using AC24 ~ 240V/DC12 ~ 240V.
And the DC specification does not have to specify the polarity.
8 action functions can be selected by the action function switch.
Combined operation of time setting switch and time unit switch,
Achieve 0.1 seconds to 9990 hours rangeCase color: Black.
Control output: Relay output.
Control mode *1: Standard or heating/cooling.
No. of auxiliary outputs: 1.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: 2.
Transfer output *2: --.
Communi cations: --.
Previous model: Thermocouple input, --;
Resistance thermometer input, --.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colors.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs.
E32-DC200F-S20 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=E32-DC200F-S20&select=5