Name: HFU (gradient temperature control) (See note 1.).
Power supply voltage: 24 VDC supplied from the End Unit.
No. of control points: None.
Control outputs 1 and 2: None.
Control outputs 3 and 4: None.
Auxiliary output: Transistor output: 4 points (sourcing).
Functions: Heater burnout alarm, None; Event inputs, 4.
Communications functions: From End Unit, Port A, RS-485; Port C, RS-422.
Input type: No input
E32-L56E2
Terminal: M3 terminal .
Gradient Temperature Control to Achieve.
Consistent Layer Temperature.
Perform gradient temperature control ranging from 2 to 32 channels.
Perform 2-channel gradient temperature control for up to 16,
groups, or 32-channel gradient temperature control for up to 2 groups.
Set gradient temperature control or 2-PID control for each group.
Reduce design work for ladder programming with programless,
connections to Programmable Controllers. (The same feature,
as Standard-control EJ1 Models.).
Connect directly to the G3ZA Multi-channel Power Controller,
using optimum cycle control for high-accuracy control with minimal noise. Model: CPM2C-20C1DTM-D. CPU Unit: Units with 20 I/O points.
2 MIL connectors.
Inputs: 12 inputs.
Outputs: 8 outputs.
Input type: 24 VDC.
Output type: sinking transistor.
Internal clock: Yes.Number of beams: 26.
Protective height: 245mm.
Model: PNP output.
Basic Type with a combination of.
performance and functionality.
Up to three sets of series-connected sensors.
The muting function is enabled simply with Muting Key Cap.
Comes standard with interlock and auxiliary output functions. Cable type: Standard Cables.
Type: Cable with Plug on One End (M12 Right-angle) .
Cable length: 10 m.
Cables and Connectors for,
EtherCAT® and Other Industrial,
Ethernet Networks. Size: 48 x 96mm.
Control output 1: current.
Auxiliary (alarm) output: 4.
Transfer output: -.
Event input: 4.
Communication: -.
Disconnection detection: 1.
Power supply voltage: DC24V/AC24V.
E5 - C series of new products program.
Maximum 256 segment of the program capacity,
Support for multiple applications.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
The use of high 25mm (E5AC-T), 18mm (E5AC-T) PV display (white),
Improve visibility.
Not only on the top of the body, but also on the front,
The use of communication adapter cable (sold separately) connected to the computer after,
No power connection can be set.
It can be easily set by CX-Thermo (sold separately).
High speed sampling to achieve 50ms.
With auxiliary output (4 points), event input (maximum 6 points), the transmission output,
Support a variety of applications.
Slender fuselage depth 60mm.
Easy to connect with PLC through no program communication.
Combined temperature control device through component communication.
Add position proportional control type, also support control valve control.
E32-L56E2 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=E32-L56E2&select=5