Element type: K (CA).
Terminal type: Exposed-terminal Models.
Protective tubing diameter D (mm): 10 dia.
Protective tubing length L: 100 cm.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal
E3F3-T86 Pressure range: 0 to 200 Pa.
Digital output: NPN open collector.
Linear output: 4 to 20 mA.
Micropressure Sensor with.
Easy-to-Read Digital Display.
Repeat accuracy of ±1% FS (setting resolution: 0.01 kPa),
high-precision pressure control available.
Compact design (31 × 30 × 30 mm) saves mounting space.
Easy-to-read red LED indicator.
Analog current output models available (E8Y-A@Y).
Pressure port Rc (PT) 1/8 models available (-R).
EN and UL approved. Cable length L: A, 1.0 m; B, 0.75 m.
Connect Connector-Terminal,
Block Conversion Units (XW2@) to,
I/O Units for Programmable,
Controllers with one touch. Output: DPDT.
Lighting: LED without Voltage Reduction Unit.
Operating voltage: 12 VAC/VDC.
Pushbutton colorsymbol: R: red, Y: yellow; PY: pure yellow
G: green, A: blue; W: white; PW: pure white.
Item: Alternate operation (Self-holding).
Separate Construction with.
Cylindrical 16-dia. Body.
Miniature design of 28.5 mm, the smallest class in the industry.
Detachable Switch.
The same contacts can be used for both standard loads and microloads.
Easy-to-wire terminal arrangement.
Certified for EN 60947-5-1. The main body: terminal type, temperature input type.
Category: control output 2 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output 1: voltage output (SSR driver).
Control output 2: voltage output (SSR driver)
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event entry point: 2.
Transfer output: -.
Communication: -.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Further performance improvement.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
E3F3-T86 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=E3F3-T86&select=5