LK Automation Limited LK Automation Limited
Brand Sort: OMRON
Home >> Price
E3Z-T81 5M Pirce
No PHOTO
OMRON E3Z-T81 5M
Actuator: Roller lever R38.
Item: Hermetic seal, Molded terminals, -139 models, Basic.
Pretravel (PT): 15±5°.
Select the Best Two-circuit Switch for the,
Operating Environment and Application,
from a Wide Range of Models,
A wide selection of models is available, including General-purpose,
Environment-resistant, and Spatter prevention Switches.
Standard-feature gold-clad crossbar contacts provide high reliability E3Z-T81 5M
Applicable to either standard loads or microloads.
Switches with Lever Actuators provide 90° overtravel,
one-side operation, and four-direction head mounting.
Approved standards: EN/IEC, UL, cUL, and CCC.
Contact your OMRON representative for information on approved models. Input / output: 40.
Pole number: 40.
I/O: input and output.
Common mode terminal: NO.
Connector mounting type: XG4A-4031.
Cable connector type: XG4M-4030-T.
The use of non threaded terminals can greatly reduce the amount of plant wiring and the required hours.
The caliper terminal so that you can no longer without fastening screws.
Only insert the rod - shaped terminal to complete a touch type wiring. Applicable CPU Units: CQM1H-CPU51/61.
Serial Communica-tions ports>Port 1: RS-232C: 19.2 kbps max., 15 m max.
Serial Communica-tions ports>Port 2: RS-422A/485: 19.2 kbps max., 500 m max.
Dimensions: 25 × 110 × 107 mm (W × H × D).
Weight: 90 g max.
Unit type: CS1 Special I/O Units.
Product name: Isolated-type,
Analog Output Unit.
Output points : 4 inputs.
Signal range selection:
Set separately for each input.
Signal range: 0 to 10 V, ±10 V,
0 to 5 V, ±5 V, 0 to 1 V, ±1 V.
Conversion speed (resolution):
40ms/4 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.12A; 26V, 0.12A.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and space compared,
with previous systems.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCUs,
to construct complete process control systems.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.
E3Z-T81 5M Operation manual/Instructions/Model selection sample download link: /searchDownload.html?Search=E3Z-T81 5M&select=5


...more relevant model market price >>>>
Related products
OMRON
Compact Photoelectric Sensor
E3Z-T81K
OMRON Compact Photoelectric Sensor E3Z-T81K
Sensing method: Through-eam Emitter
OMRON
Compact Photoelectric Sensor
E3Z-T81K-M3J
OMRON Compact Photoelectric Sensor E3Z-T81K-M3J
Sensing method: Through-eam Emitter
OMRON
Photoelectric switch
E3Z-T62-G0
OMRON Photoelectric switch E3Z-T62-G0
E3Z-T62-G0 detection methods: the firing
OMRON
Photoelectric switch
E3Z-TA Series
OMRON Photoelectric switch E3Z-TA Series
Visile light rays. Visually identify th