Contact type: Microload (125 VAC, 0.1 A; 30 VDC 0.1 A).
Operation: Momentary operation (Self-resetting).
Output: SPDT.
Lighting: Incandescent lamp, 28 VDC.
Operation Unit color symbol: Enter the desired color symbol for the Pushbutton,
in @@. R (Red); Y (Yellow); G (Green); A (Blue); W (White).
Pushbutton Switch Series with.
Square 40-mm Body.
Combines miniature design with distinct but soft sense of operation
E4E2-TS50C1 2M
Easy panel mounting from the front and simple lamp replacement.
without tools. Size: 96 x 96mm.
Ontology: terminal type, temperature input type.
Type: control output 1 point type (power AC/DC24V).
Shell color: black.
Control output: current output.
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event entry point: 2.
Transfer output: output (using control output).
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which can display the current value / target / operation.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation. Improved update. Reduce standby power consumption, and then achieve lightweight.
Standby power consumption reduced to 85% of the company''s previous products. (61F-GN)
The quality is reduced to less than 85% of the company''s previous products. (61F-G3N, G4N)
With LED action display function, so that the state of action at a glance.
By improving the reliability of internal relays (tiny load 1mA DC5V), the PLC input becomes possible.
The electrode side terminals and other wiring terminals are separated, so the wiring operation is simple.
Installation method can choose the JEM agreement, DIN guide rail installation, screw installation in 3 ways.
Type: G2N type, both full water alarm function of automatic water supply and drainage.
Package product name: 61F-G2N base * 1, 61F-11_ unit * 2.
Purpose: high sensitivity.