Size: 48 x 24mm.
Control output 1: linear current output.
Control output 2:--.
Auxiliary output: 1 points.
Power supply voltage: AC/DC24V.
Terminal type: screw terminal table type (with terminal cover).
Input category: full range multi input.
Heater break, SSR fault detection function: -.
Communication: RS-485.
Event input: -.
A small body of 48 * 24mm specifications on the condensation operation, E5_C series of high performance
E52-CA15AS 4M
Slender body width 48mm * 24mm * 90mm high depth,
The most suitable for small devices / physical and chemical equipment, etc..
Although the small size, but also through the character of the high 10.5mm white PV display to achieve high recognition.
The terminal stage is adopted to disassemble and assemble the structure, which improves the maintenance performance.
The connection method can be selected from a screw terminal and a PUSH-IN fastening terminal.
High speed sampling of 50ms is realized.
Easy to connect with PLC through no program communication.
The use of electric communication conversion Village (sold separately) connected to the computer after,
No power connection can be set.
It can be easily set by CS-Thermo (sold separately). Output: SPDT.
Lighting: LED without Voltage Reduction Unit.
Operating voltage: 5 VDC.
Pushbutton colorsymbol: R: red, Y: yellow; PY: pure yellow
G: green, A: blue; W: white; PW: pure white.
Item: Momentary operation (Self-resetting).
Separate Construction with.
Cylindrical 16-dia. Body.
Miniature design of 28.5 mm, the smallest class in the industry.
Detachable Switch.
The same contacts can be used for both standard loads and microloads.
Easy-to-wire terminal arrangement.
Certified for EN 60947-5-1. Time specification: Inverse type.
Current setting range: 50 to 160 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Automatic.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
E52-CA15AS 4M Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=E52-CA15AS 4M&select=5