LK Automation Limited LK Automation Limited
Brand Sort: OMRON
Home >> Price
E5CN-HV201-FLK AC100-240 Pirce
No PHOTO
OMRON E5CN-HV201-FLK AC100-240
Type: 1a1b welding terminal.
Shape: square.
Type: General load.
Motor function: alternate action (self retaining).
With light: LED with light.
Using voltage: DC5V.
Operation Department color: yellow.
20mm long, with 12 round series
High brightness all one side light.
Because it is round, so easy to punch.
Miniaturization, operation feel good. I/O classification: Digital output.
Internal I/O circuit common: NPN (- common) E5CN-HV201-FLK AC100-240
I/O points: 8.
I/O connection method: Sensor connector.
Compact Remote I/O Terminals that.
Save Wiring Effort and Enable.
Long-distance Communications.
Long-distance or high-speed communications,
mode is selectable.
Incorporates I/O connectors making it possible to,
minimize the size.
I/O connectors save wiring effort.
Flexible DIN track mounting is possible through a,
DIN track attachment.
Eight-point sensor connector models and 16-point,
MIL connector models are the same size. Size: 48 * 48mm, terminal type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: current output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: -.
Event input points: -.
Transfer output: output (using control output).
Communication: RS-232C.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms.
Full of all models (capable of thermocouple /Pt/ analog input switching),
1 machines to support a variety of sensors.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm),
Interactive display PV/SV.
By supporting software (Ver.4.3 CX-Thermo),
In simple arithmetic functions (AND/OR logic and delay).
Setting the program settings that can perform flexible contact output.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller.
E5CN-HV201-FLK AC100-240 Operation manual/Instructions/Model selection sample download link: /searchDownload.html?Search=E5CN-HV201-FLK AC100-240&select=5


...more relevant model market price >>>>
Related products
OMRON
Power monitor
KM100-T-FLK AC100-240
OMRON Power monitor KM100-T-FLK AC100-240
Category: ontology power monitoring. Ap
OMRON
Power monitor
KM100-TM-FLK AC100-240
OMRON Power monitor KM100-TM-FLK AC100-240
Category: ontology power monitoring. Ap