LK Automation Limited LK Automation Limited
Brand: OMRON
Go Back >> Product Catalogues
3G3AX-DL4220 | OMRON DC reactor 3G3AX-DL4220

OMRON 3G3AX-DL4220 Product information and technical parameters:
Brand: OMRON
Name: DC reactor
Model: 3G3AX-DL4220
Frequency converter input power: 3 phase AC400V.
Weight: 9.0KG.
Standard applicable line diameter: 60 square mm or more.
Used to suppress harmonic currents generated by a transducer.
The effect of harmonic current suppression is better than that of AC reactor,
And it can be used with AC reactor.

Function name: 3 phase 200V.
Power: 7.5KW.
Rated output voltage: 3 phase, 200 ~ 240V (the output voltage can not exceed the input voltage).
Built in brake unit (brake resistance needs to be matched).
Weight: 3.4KG.
Dimension (w * h) 260mm *:140.
Outline dimension (deep):155mm.
Mechanical automation concept OMRON 3G3AX-DL4220.
Positioning function.
The use of options.
(EtherCAT, CompoNet and DeviceNet) to realize the field bus communication 3G3AX-DL4220
Driver programming function.
Current vector control.
High starting torque: 0.5Hz up to 200%.
Safety features, in compliance with ISO13849-1:2008 EN (Cat.3/PLd) and IEC60204-1 stop level 0 standard.
Frequency output up to 580H. Function name: 3 phase 200V.
Power: 5.5KW.
Rated output voltage: 3 phase, 200 ~ 240V (the output voltage can not exceed the input voltage) OMRON 3G3AX-DL4220.
Built in brake unit (brake resistance needs to be matched).
Weight: 3.3KG.
Dimension (w * h) 260mm *:140.
Outline dimension (deep):155mm.
Mechanical automation concept.
Positioning function.
The use of options.
(EtherCAT, CompoNet and DeviceNet) to realize the field bus communication.
Driver programming function OMRON 3G3AX-DL4220.
Current vector control.
High starting torque: 0.5Hz up to 200%.
Safety features, in compliance with ISO13849-1:2008 EN (Cat.3/PLd) and IEC60204-1 stop level 0 standard.
Frequency output up to 580H. Function name: 3 phase 200V.
Power: 0.2KW.
Rated output voltage: 3 phase, 200 ~ 240V (the output voltage can not exceed the input voltage).
Built in brake unit (brake resistance needs to be matched).
Weight: 1.0KG.
Dimension (w * h) 128mm *:68.
Outline dimension (deep):109mm.
Mechanical automation concept.
Positioning function.
The use of options.
(EtherCAT, CompoNet and DeviceNet) to realize the field bus communication.
Driver programming function.
Current vector control.
High starting torque: 0.5Hz up to 200%.
Safety features, in compliance with ISO13849-1:2008 EN (Cat.3/PLd) and IEC60204-1 stop level 0 standard.
Frequency output up to 580H. Level: 3 phase 400V levell 3G3AX-DL4220.
Connecting resistance: 34 or more.
Internal resistance value: 120W, 180W * 2 (series).
In 3G3MX2 with the use of the braking resistor, can shorten the motor deceleration time.
Alarm output terminal of regenerative braking unit.
The ttemperature relay built-in resistance or braking resistance optional activation,
A circuit to cut off the main power supply of the frequency converter 3G3AX-DL4220.


...More relevant models >>>>