Name: e-CON Connectors.
Disconnected Line Detection.
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
wiring in the system.
contribute to system size reduction.
helps to detect errors on site.
content of the error.
Unit type: 10 I/O points 6 inputs; 4 outputs, Connector.
Input: 6 points: 24 VDC.
Output: 4 points: transistor (sinking).
Clock: Yes.
Slaves with the Complex Functionality Needed,
for Distributed Blocks.
Programmable Slaves combine devices, such as sensors and actuators,
into one functional unit that is treated as a DeviceNet slave OMRON CRT1-MD16SH.
Programmable Slaves greatly facilitate device distribution,
and functional organization
CRT1-MD16SH
They help standardize programming between units and reduce the amount of,
programming required at the master.
I/O and operational checks can be performed for each functional unit,
rather than waiting.
for final system assembly, as with conventional distributed I/O systems OMRON CRT1-MD16SH. Name: Slice I/O Units; Digital I/O Units.
Specifications: 4 outputs NPN.
Standards: CE, UC1, L, N.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction OMRON CRT1-MD16SH.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. Name: e-CON Connectors.
Specifications: Inputs; 8 inputs ; PNP;
Without Short-circuit and,
Disconnected Line Detection.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. I/O classification: Output.
Internal I/O circuit common: NPN (- common).
I/O points: 8.
Rated voltage: 24 VDC.
I/O rated voltage: 24 VDC.
Long-distance Communications Supporteed by SRT2 Models,
(Long-distance/High-speed Communications Selection) CRT1-MD16SH.
Ultra-compact at 80 x 48 x 50 (W x H x D) mm for,
4-point and 8-point terminals and 105 x 48 x 50,
(W x H x D) mm for 16-point terminals.
Two independent power supplies can be used,
because the I/O terminals are insulated from the internal circuits CRT1-MD16SH.
DIN track mounting and screw mounting are both supported.