Actuator: Adjustable roller lever, form lock (metal lever, resin roller).
Conduit size: 1-conduit; Pg13.5.
Built-in switch mechanism: 1NC/1NO MBB(Slow-action).
Popular Safety Limit Switches.
International Standards.
3NC contact forms.
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only).
Certified standards: UL, EN (TÜV), and CCC.
Actuator: Plunger.
Conduit size: 1-conduit; M20.
Built-in switch mechanism: 3NC (Slow-action).
A Series of Pull-reset Models Now.
Available.
Lineup includes three contact models with 2NC/1NO and 3NC,
contact forms in addition to the previous contact forms 1NC/1NO and 2NC.
M12-connector models are available, saving on labor and,
simplifying replacement OMRON D4N-1E2G.
Standardized gold-clad contacts provide high contact reliability
D4N-1E2G
Can be used with both standard loads and microloads.
Conforms to EN115, EN81-1 and EN81-2.
Certified standards: UL, EN (TÜV), and CCC. Actuator: One-way roller arm lever (vertical).
Conduit size: 1-conduit; G1/2.
Built-in switch mechanism: 2NC/1NO MBB (Slow-action) OMRON D4N-1E2G.
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms.
(Slow-action models with MBB contacts are available.)
M12-connector models are also available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads OMRON D4N-1E2G.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only).
Certified standards: UL, EN (TÜV), and CCC. Number of beams: 32.
Protective height: 640mm.
Safety Light Curtains with Durable,
Impact-resistant Body and Long,
20-m Sensing Distance.
MS/MSF4800A Advanced Series.
Programming and Diagnostics Module (PDM) makes it easy,
to set functions.
Series connection is possible only with the MSF4800A.
Blanking can be set.
Muting is possible only with the MSF4800A by using the,
MS4800-RM6 Resource Module.
MS/MSF4800B Basic Series,
Features all necessary basic Safety Light Curtain functions.
Series connection is possible only with the MSF4800B.
Programming and Diagnostics Module (PDM) makes it easy,
to set functions. Safety outputs *3: Instantaneous, 2(semiconductor);
OFF-delayed *2: 2 (semiconductor).
Auxiliary outputs *4: 6 (semiconductor).
Logical AND connection: Inputs, 1 (semiconductor);
Outputs, 1 (semiconductor).
Max.OFF-delay time *1: 15 s.
Rated voltage: 24 VDC.
Terminal block type: Spring-cage terminals.
A Safety Measure for Hazardous Operations.
That Does Not Lower Productivity.
Two functions support two types of application:
Auto switching: For applications where operators work,
together with machines.
Manual switching: For applications with limited operations.
External indicator outputs enable indicating the switching statuss,
of two safety input devices D4N-1E2G.
Auxiliary outputs enable monitoring of safety inputs, safety,
outputs, and errors.
Detailed LED indications enable easy diagnosis.
Logical AND connection allows complicated applications in,
combination with other G9SX-series Units D4N-1E2G.
Certification for compliance with IEC/EN 61508 (SIL3), IEC/EN,
62061 (SIL3) and EN ISO13849-1 (PLe/Safety Category 4).