Number of beams: 80.
Protective height: 731mm.
Model: PNP output.
Basic Type with a combination of.
performance and functionality.
Up to three sets of series-connected sensors.
The muting function is enabled simply with Muting Key Cap.
Comes standard with interlock and auxiliary output functions OMRON D4SL-N2PFG-D4N. The G9SA Series Offers a Complete.
Line-up of Compact Units.
Four kinds of 45-mm wide Units are available:
A 3-pole model, a 5-pole model, and models with 3 poles,
and 2 OFF-delay poles, as well as a Two-hand Controller
D4SL-N2PFG-D4N
Also available are 17.5-mm wide Expansion Units with 3,
poles and 3 OFF-delay poles.
Simple expansion connection.
OFF-delay models have 15-step OFF-delay settings.
Conforms to EN ISO13849-1 (PLe/Safety Category 4) OMRON D4SL-N2PFG-D4N.
Both DIN track mounting and screw mounting are possible. Actuator: One-way roller arm lever (vertical).
Conduit size: 1-conduit; M12 connector.
Built-in switch mechanism: 2NC (Slow-action).
A Series of Pull-reset Models Now.
Available.
Lineup includes three contact models with 2NC/1NO and 3NC,
contact forms in addition to the previous contact forms 1NC/1NO and 2NC OMRON D4SL-N2PFG-D4N.
M12-connector models are available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115, EN81-1 and EN81-2.
Certified standards: UL, EN (TÜV), and CCC. Release Key Type: Standard (metal).
Wiring method: Connector.
Solenoid voltage/Indicator: 24VDC (without indicator).
Lock and release type: Solenoid lock Mechanical release.
Contact configuration (door open/closed detection switch,
and lock monitor switch contacts): 4-contact Model,
Insert the built-in switch (A, B, C, D, S, T, U or V) into the blank @.
Conduit size (See Note.): 1/2-14NPT.
World''s smallest Class 6-contact Guard Lock.
Safety-door Switch.
.
Wiring time is reduced with two types of wiring.
methods capable of one-touch attachment and removal.
A wide variety of built-in switches can be used for various devices.
(4-, 5-, and 6-contact models are available).
Key holding force of 1,300 N.
It is possible to change the key iinsertion point D4SL-N2PFG-D4N.
without detaching the head.
Drive solenoids directly from the Controller.
.
Lockout Key to prevent workers from becoming.
trapped inside the hazardous area.
The vertical D4SL Guard Lockk Safety-door Switch,
can be easily mounted on 40 × 40 mm aluminum frames D4SL-N2PFG-D4N.
The plastic material makes the Slide Key suitable,
for lightweight doors.