LK Automation Limited LK Automation Limited
Brand: OMRON
Go Back >> Product Catalogues
DRT2-AD04 | OMRON Analog I/O Terminals DRT2-AD04
OMRON DRT2-AD04 Manual And Instructions
DRT2-AD04 datasheetPDF datasheet
DRT2-AD04 PROGRAMMING MANUAL
DRT2-AD04 INSTRUCTION Manual

OMRON DRT2-AD04 Product information and technical parameters:
Brand: OMRON
Name: Analog I/O Terminals
Model: DRT2-AD04
Classification: Analog input.
I/O points: 4 inputs (Resolution: 6, 000).
Performs Calculations on Analog Values within the Slave Itself.
Also Provides High Resolution at 1/30,000 (Full Scale) and,
Support for a Wide Variety of Data Sampling.
Equipped with the standard Smart Slave functions that provide powerful,
preventative maintenance and troubleshooting capabilities.
Sampling data can be analyzed internally to provide a low-cost scheduler function.
Equipped with functions such as the scaling function, peak/bottom hold;
top/valley hold; comparator function, cumulative counter, and derivative,
calculation function.
Two I/O points can be allocated to any two of the following values: analog,
input, peak/bottom, top, valley, or rate-of-change. Values without an,
allocated I/O point can be read with message communications.

Name: Three-tier Screw Terminal Block.
Specifications: Inputs; 8 inputs; PNP;
With Short-circuit and,
Disconnected Line Detection.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system OMRON DRT2-AD04.
A wide variety of CompoNet Slave Units,
contribute to system size reduction DRT2-AD04
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. Name: Clamp Terminal Blocks.
Specifications: Outputs; 16 outputs ; PNP; -- OMRON DRT2-AD04.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site OMRON DRT2-AD04.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. Specifications: Outputs; PNP (+ common);
16 points.
I/O connections: M3 screw terminals.
Rated internal circuit power supply voltage:
Supplied from Basic Unit.
I/O power supply voltage: 24 VDC.
A Smart Slave with a 3-tier Terminal,
Block That Means Wiring Locations,
Are Easy to Understand with No,
Sharing of Terminals.
Easy wiring with no sharing of terminals.
Easy-to-understand wiring locations.
No relay terminal block terminals required.
Detachable cassette-type circuit sections. Unit: High-density connector model.
I/O classification: Digital input.
Internal I/O common: PNP (- common).
I/O points: 32.
I/O connnections: Fujitsu connector DRT2-AD04.
Power supplyvoltage: 24 VDC.
I/O specification: DC/transistor.
Digital I/O Units Compatible with MULTIPLE I/O TERMINAL,
Terminal block, connector, and high-density connector,
models are available.
The ciircuit block of the terminal block model can be,
mounted or dismounted for ease of maintenance without,
disconnecting the wires DRT2-AD04.
DIN track mounting.


...More relevant models >>>>