OMRON DRT2-OD08-1 Product information and technical parameters:
Brand: OMRON
Name: Transistor Remote I/O Terminals
Model: DRT2-OD08-1
Specifications: Outputs; PNP (+ common); 8 points.
I/O connections: M3 Screw terminals.
Rated internal circuit power supply voltage:
Supplied from the communications connector.
Rated I/O power supply voltage: 24 VDC.
Allows I/O Expansion with Transistor Terminals.
Wide variety of data, such as maintenance system data,
can be collected without affecting the productivity,
of the control system.
Valuable information can be collected,
and managed through the network, including information,
on the communications power supply.
voltage levels, Unit wear and tear,
and equipment operating information.
Expansion via Expansion I/O Units.
With no communications baud rate settings,
required and detachable terminal blocks,
maintenance is easier.

Name: e-CON Connectors.
Specifications: Inputs/Outputs;
8 inputs /8 outputs; NPN;
Without Short-circuit and,
Disconnected Line Detection.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system OMRON DRT2-OD08-1.
A wide variety of CompoNet Slave Units,
contribute to system size reduction DRT2-OD08-1
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. Short/disconnection detection: Supported OMRON DRT2-OD08-1.
Specifications: Inputs, NPN (+ common), 16 points.
I/O connections: Clamp terminals.
Rated internal circuit power supply voltage:
Supplied from communications connector.
Rated I/O power supply voltage: 24 VDC.
Reduced Wiring and Labor on Factory Sites with Screw-less Terminal Wiring.
Screw-less structure eliminates tightening work.
Detachable terminal blocks for easier maintenance.
Single-step wiring by simply inserting pole terminals OMRON DRT2-OD08-1. Name: e-CON Connector Type.
Specifications: Analog inputs;
4 inputs.
Standards: CE, UC, UC1.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. I/O classification: Digital I/O.
Internal I/O circuit common: NPN (- common).
I/O points: 16.
I/O connection method: M3 terminaal block DRT2-OD08-1.
Models with 3-tier Terminals (16 Points),
Added to the Remote I/O Terminal Series.
Six Models are Available Depending on the,
NPN or PNP Configuration, Input Points,
I/O Points, or Output Points.
Incorporates easy-to-wiree terminals each,
connecting to a single wire DRT2-OD08-1.
Reduces designing and wiring effort.
Incorporates a removable circuit block of cassette construction.


...More relevant models >>>>
Last one: OMRON DRT2-OD08
next one: OMRON DRT2-ROS16