LK Automation Limited LK Automation Limited
Brand: OMRON
Go Back >> Product Catalogues
DRT2-OD08C-1 | OMRON Environment-resistive Terminals with Transistors DRT2-OD08C-1
OMRON DRT2-OD08C-1 Manual And Instructions
DRT2-OD08C-1 datasheetPDF datasheet
DRT2-OD08C-1 Operation Manual
DRT2-OD08C-1 INSTRUCTION Manual

OMRON DRT2-OD08C-1 Product information and technical parameters:
Brand: OMRON
Name: Environment-resistive Terminals with Transistors
Model: DRT2-OD08C-1
Specifications: Output, PNP (+ common), 8 points.
I/O connections: Sensor I/O connector.
Rated internal circuit power supply voltage:
Supplied from the communications connector.
Rated I/O power supply voltage: 24 VDC.
Environment-resistive (IP67) I/O.
Terminals with Troubleshooting.
Functions such as Sensor Power.
Supply Short-circuit Detection.
Equipped with the standard Smart Slave functions that provide powerful,
preventative maintenance and troubleshooting capabilities.
High degree of environmental resistance with dust-proof,
and drip-proofconstruction.
Power supply wiring is not required for input devices.
Connect heavy-load devices (up to 1.5 A).
Power supply wiring is not required for input devices such as sensors.
(Power supply wiring is required for output devices.)
Detects ground faults or disconnects and notifies the Master.

Specifications: Inputs, NPN(+ common), 32 inputs.
I/O connections: MIL connector.
Rated internal circuit power supply voltage:
Supplied from communications connector.
Rated I/O power supply voltage: 24 VDC.
First Board-type Terminals for Smart Slaves!
Easily modified to handle an array of I/O interfaces,
and eliminates much on-site wiring OMRON DRT2-OD08C-1.
User boards attach easily to the DRT2-@D32BV(-1) using screws DRT2-OD08C-1 Specifications: Outputs; NPN (- common); 16 points.
I/O connections: M3 Screw terminals.
Rated internal circuit power supply voltage:
Supplied from the communications connector.
Rated I/O power supply voltage: 24 VDC.
Allows I/O Expansion with Transistor Terminals.
Wide variety of data, such as maintenance system data,
can be collected without affecting the productivity,
of the control system OMRON DRT2-OD08C-1.
Valuable information can be collected,
and managed through the network, including information,
on the communications power supply.
voltage levels, Unit wear and tear,
and equipment operating information.
Expansion via Expansion I/O Units.
With no communications baud rate settings,
required and detachable terminal blocks,
maintenance is easier OMRON DRT2-OD08C-1. Unit: Connector model.
I/O classification: Digital input.
Internal I/O common: NPN (+ common).
I/O points: 16.
I/O connections: D-sub 25-pin connector.
Power supplyvoltage: 24 VDC.
I/O specification: DC/transistor.
Digital I/O Units Compatible with MULTIPLE I/O TERMINAL,
Terminal block, connector, and high-density connector,
models are available.
The circuit block of the terminal block model can be,
mounted or dismounted for ease of maintenance without,
disconnecting the wires.
DIN track mounting. Specifications: Outputs;
NPN (- common);
16 poinnts DRT2-OD08C-1.
I/O connections: MIL connector(Connector with 10-cm cable).
Rated internal circuit power supply voltage:
Supplied from the communications connector.
Rated I/O power supply voltage: 24 VDC.
Very Compact 16-/32-point Remote Termminals DRT2-OD08C-1.
Used in combination with Interface,
Conversion Boards (e.g., D-Sub) to,
connect to a wide range of interfaces.
35 x 60 x 80 mm (W x D x H).