Size: M8, Non-shielded.
Sensing distance: 4.0 mm.
Connection: Pre-wired.
Body material: Stainless steel.
Thread length (overall length): 27 (40).
Output configuration: PNP.
Operation mode NC.
Safe Mounting with Greater.
Sensing Distance.
times larger than that of any conventional OMRON Sensor.
Problems such as the collision of workpieces are eliminated.
M30; both long and short barrels).
Modular construction simplifies customization.
Size: M8(Stainless steel)(See note 2.); Double; Shielded.
Sensing distance: 2 mm.
Connecting method (See note 1.): Pre-wired.
Body length: Short.
Output configuration: PNP.
Operation mode NO.
A new generation in global applications. Appearance: M12.
Sensing distance: 5 mm.
Connection method: M12 Connector Models OMRON E2A-S08KN04-WP-B2 2M.
Cable specifications: --.
Operation mode : NO
E2A-S08KN04-WP-B2 2M
Pin arrangement: 1: +V, 3: 0 V, 4: Control output.
Applicable connector code: B.
Model: PNP output.
Your Search for Proximity Sensors.
Starts with the World-leading.
Performance and Quality of the E2E.
Standard Sensors for detecting ferrous metals.
Wide array of variations. Ideal for a variety of applications.
Models with different frequencies are also available to prevent,
mutual interference OMRON E2A-S08KN04-WP-B2 2M.
Superior environment resistance with standard cable made of oil,
resistant PVC and sensing surface made of material that resists,
cutting oil.
Useful to help prevent disconnection.
Cable protector provided as a standard feature. Sensing method: Through-beam type.
Sensing distance(slot width): 3.6 mm.
Output type: NPN output OMRON E2A-S08KN04-WP-B2 2M.
Output configuration: Light-ON.
Cable length: 1 m.
Photomicrosensor with built-in,
amplifier and attached cable reduces,
external light interference.
Light modulation effectively reduces external light interference.
Wide operation voltage range: 5 to 24 VDC.
Easy operation monitoring with bright light indicator. E3JK-R2M1 detection method: Regression reflection type with M.S.R. function,
Connection mode: lead wire,
Detection range: 2.5m.
Output status: ON.
Output: relay,
2 types of cost reductionFree change detection direction.
Detection direction can be according to the front, side (up and down, around 90 units) change.
Can be similar to the feeling of a limit switch installation.
Type: deteection of variable terminal plate / DC type E2A-S08KN04-WP-B2 2M.
Shape: non shield.
Detection range: 30mm.
Output form: NO NPN + NC (dual output). Size: M8(Stainless steel)(See note 2.); Double; Shielded.
Sensing distance: 2 mm.
Connecting metthod (See note 1 E2A-S08KN04-WP-B2 2M. ): M8 Connector (3-pin).
Body length: Long.
Output configuration: NPN.
Operation mode NC.
A new generation in global applications.