Terminal type: Exposed-lead Models.
Protective tubing diameter D(mm): 1 dia.
Protective tubing length L: 35 cm.
Lead wire type: Standard.
Lead wire length M: 8m.
A Wide Variety of High-precision.
Temperature Sensors.
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
and also according to the type and shape of the terminal.
Size: 48 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 2 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output 1: current output.
Control output 2: high life relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 3 points OMRON E52-CA35AF D=1 8M.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use
E52-CA35AF D=1 8M
Event input points: -.
Transfer output: output (using control output).
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance OMRON E52-CA35AF D=1 8M.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which can display the current value / target / operation OMRON E52-CA35AF D=1 8M.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation. Terminal type: Exposed-lead Models.
Protective tubing diameter D (mm): 8 dia.
Protective tubing length L: 50 cm.
Lead wire type: Standard.
Lead wire length M : 2m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Size: 96 × 96 mm.
Control type: 2-loop control .
Control mode: 2-loop standard control, Single-loop heating and cooling control,
Single-loop cascade control, Single-loop control with remote SP,
Single-loop proportional control.
Outputs(control/transfer): 2 (pulse + pulse/current).
Optional functions: Auxiliary outputs (SUB), 4;
Event inputs, 4; Serial communications, RS-485.
AA new High-speed, High-precision Digital E52-CA35AF D=1 8M.
Controller that is Programmable!
Create up to 32 programs with up to 256 segments total.
Coordinated operation for up to four channels with one Digital Controller.
0.01°C High resolutioon for Pt input E52-CA35AF D=1 8M.
High-speed sampling at 50 ms.
Settings easily made from a computer using the CX-Thermo.
RoHS compliance for world-wide application.