LK Automation Limited LK Automation Limited
Brand: OMRON
Go Back >> Product Catalogues
E5AC-RX2ASM-008 | OMRON Digital temperature controller E5AC-RX2ASM-008
OMRON E5AC-RX2ASM-008 Manual And Instructions
E5AC-RX2ASM-008 datasheetPDF datasheet
E5AC-RX2ASM-008 datasheetPDF datasheet
E5AC-RX2ASM-008 RS-485 CompoWay/Flnstruction Manual
E5AC-RX2ASM-008 INSTRUCTION Manual

OMRON E5AC-RX2ASM-008 Product information and technical parameters:
Brand: OMRON
Name: Digital temperature controller
Model: E5AC-RX2ASM-008
Size: 96 x 96mm.
Control output 1: relay output.
Control output 2:--.
Auxiliary output: 2 independent points.
Power supply voltage: AC100 ~ 240V.
Terminal shape: screw terminal table type.
Input category: full range multi input.
Heating wire break, SSR fault detection function: 1 points.
Communication: RS-485.
Event input: 2 points.
Remote SP input: -.
Transfer output: -.
Large screen display white PV legible. From selection to setting and operation are simple and easy to use.
Full capacity, function and performance of I/O. Suitable for more applications.
E5AC white LCDPV display height is about 25mm.
The upper panel and the front panel are equipped with tool ports.
With the communication conversion line (sold separately) connected to the computer to establish the controller without the need to install the wire for power supply.
Easy to install CX-Thermo (sold separately).
50ms high speed sampling period.
Model can be equipped with up to 4 point auxiliary output, 6 point event input,
1 point transfer output and remote SP input, suitable for a wide range of applications.
The main body is short, the thickness is only 60mm.
Easy to use programmable logic controller (PLC) is connected to the programmable logic controller (PLC).
The temperature controller is connected to each other by using the component communication.
A new type of proportional control allows you to control the valve.

Size: 48 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 2 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output 1: relay output.
Control output 2: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 3 points OMRON E5AC-RX2ASM-008.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use E5AC-RX2ASM-008
Event entry point: 2.
Transfer output: -.
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance OMRON E5AC-RX2ASM-008.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which can display the current value / target / operation.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc OMRON E5AC-RX2ASM-008. , can be a key operation. Size: DIN 1/4, 96 x 96 x 78mm.
Power supply voltage: AC100 ~ 240V.
Alarm points: 3 points.
Control output: voltage output (for driving a bidirectional thyristor switching element).
Input: Platinum resistance.
New generation intelligent general temperature controller.
The thickness is only 78 mm.
Various temperature inputs: thermocouple, platinum resistance, non contact temperature sensor signal input.
Automatic adjustment and self adjustment.
Automatic adjustment can be performed even when the self adjustment is being performed. Case color: Black.
Control output: Current output.
Control mode *1: Standard or heating/cooling.
No. of auxiliary outputs: 1.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: --.
Transfer output *2: Transfer output using control output.
Communi cations: --.
Previous model: Thermocouple input, --;
Resistance thermometer input, --.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status off the Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV E5AC-RX2ASM-008.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colorrs E5AC-RX2ASM-008.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs.


...More relevant models >>>>