Auxiliary output: 4 points (auxiliary output 2, 1 common, auxiliary output 3, 4 public general).
Heating wire break, SSR fault detection function: 2 point (three phase heater).
Large screen display white PV legible. From selection to setting and operation are simple and easy to use.
Full capacity, function and performance of I/O. Suitable for more applications.
With the communication conversion line (sold separately) connected to the computer to establish the controller without the need to install the wire for power supply.
Model can be equipped with up to 4 point auxiliary output, 6 point event input,
1 point transfer output and remote SP input, suitable for a wide range of applications.
Easy to use programmable logic controller (PLC) is connected to the programmable logic controller (PLC).
The temperature controller is connected to each other by using the component communication.
A new type of proportional control allows you to control the valve.
Size: 96 × 96 mm.
Control type: Basic control (1 loop).
Control mode: Single-loop standard control Single-loop heating and cooling control.
Outputs(control/transfer): 2 points: Current and Current.
Optional functions: Auxiliary outputs (SUB), 4;
Event inputs, 2; Serial communications, No.
E5AR Digital Controllers offer high speed,
high precision, and multiple I/O and use a 5-digit,
3-row LCD display for high visual clarity OMRON E5AC-RX4DSM-009
E5AC-RX4DSM-009
A short sampling period of 50 ms enables use in applications,
requiring high-speed response.
PV, SP, and MV data is displayed simultaneously in a 3-row,
negative LCD display with a backlight.
Multiloop control, cascade control, and proportional control are,
possible with a single Controller OMRON E5AC-RX4DSM-009.
When using models with CompoWay/F communications, initial,
settings can be downloaded and settings can be masked using,
Support Software (CX-Thermo version 4.0 or higher).
Equipped with calculation functions as a standard (e.g., square,
root calculation and broken-line approximation).
DeviceNet Communications.
Data setting and monitoring can be performed without special programming OMRON E5AC-RX4DSM-009. Name: Basic Unit (temperature control) *1.
Power supply voltage: 24 VDC supplied from the End Unit.
No. of control points: 4.
Control outputs 1 and 2: Voltage output: 2 points (for SSR drive) *2.
Control outputs 3 and 4: Voltage output: 2 points (for SSR drive) *2.
Auxiliary output: None.
Functions: burnout Heater alarm, None; Event inputs, None .
Communications functions: G3ZA connection port: RS-485,
From End Unit: Port A or port B: RS-485.
Input type: Thermocouple, platinum resistance thermometer,
analog voltage, and analog current selectable for each channel.
Terminal: M3 terminal.
In-panel Temperature Controller with Flexible,
Modular Design and Wide Integration with Host,
Devices.
The compact modular structure enables construction of temperature,
systems optimally suited to the application.
Connection can be made to a Programmable Controller without any,
programming required, reducing the number of steps required in ladder,
programming design.
One fully universal-input Unit includes a thermocouple, platinum-resistance,
thermometer, and analog input for easy selection and reduced inventory,
requirements.
Connect directly to the G3ZA Multi-channel Power Controller using,
optimum cycle control for high-accuracy regulation with minimal noise E5AC-RX4DSM-009.
Autotuning (AT) can be used for independent heating/cooling PID control.
Self-tuning (ST) can be used to calcullate the PID constants with the step,
response method E5AC-RX4DSM-009.
Up to 16 Temperature Controllers can be connected to a single DeviceNet,
Communications Unit.