E5AN-HSS2HHBFD | OMRON High performance temperature controller E5AN-HSS2HHBFD
OMRON E5AN-HSS2HHBFD Manual And Instructions
E5AN-HSS2HHBFD datasheetPDF datasheet
E5AN-HSS2HHBFD User's Manual
E5AN-HSS2HHBFD Basic TypeUser's Manual
E5AN-HSS2HHBFD User's Manual
E5AN-HSS2HHBFD User's Manual
E5AN-HSS2HHBFD Communications FunctionsUser's Manual
E5AN-HSS2HHBFD INSTRUCTION Manual

OMRON E5AN-HSS2HHBFD Product information and technical parameters:
Brand: OMRON
Name: High performance temperature controller
Model: E5AN-HSS2HHBFD
Size: 96 x 96mm.
Type: power AC/DC24V with.
Shell color: black.
Control output 1: built-in SSR output.
Control output 2: built-in SSR output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
The detection function of the broken wire and SSR fault of heater: detection function of single phase or three phase heater.
Event entry point: 2.
Transfer output: transfer output (special terminal).
Remote SP:4 to 20mA input.
Communication: -.
General thermostat new high performance (high resolution, high speed, high precision input) type products.
Support simple operation, preventive maintenance.
A new type of liquid crystal, which can communicate with the front through the infrared port, is adopted,
Visual angle, contrast can be improved.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV.
By supporting software (Ver.4.0 CX-Thermo) to carry out a simple function (AND/OR logic and delay),
Be able to execute flexible contact output.
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay fault.
Position ratio type.

Size: 48 x 48mm.
Control output 1: voltage output (SSR driver).
Control output 2: voltage output (SSR driver).
Auxiliary output: 3 points (common universal).
Power supply voltage: AC100 ~ 240V.
Terminal type: screw terminal table type.
Input category: full range multi input.
Heater break, SSR fault detection function: - OMRON E5AN-HSS2HHBFD.
Communication: RS-485.
Event input: 2 points.
Remote SP input: - E5AN-HSS2HHBFD
Transfer output: -.
Using large font PV display (white), improve visibility.
Selection, operation and setting.
Functional performance of input and output points.
Support for more extensive range of applications.
Using high PV 15.2mm display (white), improve visibility.
High speed sampling to achieve 50ms OMRON E5AN-HSS2HHBFD.
With auxiliary output (maximum 3 points), event input (maximum 4 points), the transmission output,
Remote SP input function, support for a variety of applications.
E5CC 60mm has a depth of slender body.
The use of communication adapter cable (sold separately) connected with a computer.
After that, no power supply connection can be set.
It can be easily set by CX-Thermo (sold separately) OMRON E5AN-HSS2HHBFD.
Easy to connect with PLC through no program communication.
Combined temperature control device through component communication. Terminal type: Exposed-lead Models.
Protective tubing diameter D (mm): 8 dia. . .
Protective tubing length L: 20cm.
Lead wire type: Heat resistive.
Lead wire length M : 4m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. The main body: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: single phase heater with detection function.
Event input points: -.
Transfer output: -.
Communication: RS-485.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Further performance improvement E5AN-HSS2HHBFD.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactivee display PV/SV E5AN-HSS2HHBFD.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.