LK Automation Limited LK Automation Limited
Brand: OMRON
Go Back >> Product Catalogues
E5CN-HTQQ203D-FLK | OMRON Programmed temperature controller E5CN-HTQQ203D-FLK
OMRON E5CN-HTQQ203D-FLK Manual And Instructions
E5CN-HTQQ203D-FLK datasheetPDF datasheet
E5CN-HTQQ203D-FLK Programmable TypeBasic Type
E5CN-HTQQ203D-FLK Programmable TypeUser's Manual
E5CN-HTQQ203D-FLK User's Manual
E5CN-HTQQ203D-FLK Basic TypeBasic Type
E5CN-HTQQ203D-FLK User's Manual
E5CN-HTQQ203D-FLK User's Manual
E5CN-HTQQ203D-FLK Communications FunctionsUser's Manual
E5CN-HTQQ203D-FLK USER'S MANUAL
E5CN-HTQQ203D-FLK Communications FunctionsUser's Manual
E5CN-HTQQ203D-FLK USER'S MANUAL
E5CN-HTQQ203D-FLK INSTRUCTION Manual

OMRON E5CN-HTQQ203D-FLK Product information and technical parameters:
Brand: OMRON
Name: Programmed temperature controller
Model: E5CN-HTQQ203D-FLK
Size: 48 * 48mm, terminal type.
Type: control output 2 point type (power AC/DC24V).
Shell color: black.
Control output 1: voltage output (SSR driver).
Control output 2: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase or three phase heater detection function.
Event input points: -.
Transfer output: -.
Communication: RS-485.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms.
Full of all models (capable of thermocouple /Pt/ analog input switching),
1 machines to support a variety of sensors.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm),
Interactive display PV/SV.
By supporting software (Ver.4.3 CX-Thermo),
In simple arithmetic functions (AND/OR logic and delay).
Setting the program settings that can perform flexible contact output.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller.

Lead wire length: 1m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal OMRON E5CN-HTQQ203D-FLK E5CN-HTQQ203D-FLK Size: 96 x 96mm.
Category: power AC100 ~ 240V with.
Shell color: silver.
Control output 1: output unit mode.
Control output 2: output unit mode.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
The detection function of the broken wire and SSR fault of heater: detection function of single phase or three phase heater OMRON E5CN-HTQQ203D-FLK.
Event entry point: 4.
Transfer output: -.
Remote SP:4 to 20mA input.
Communication: -.
General thermostat new high performance (high resolution, high speed, high precision input) type products.
Support simple operation, preventive maintenance.
A new type of liquid crystal, which can communicate with the front through the infrared port, is adopted,
Visual angle, contrast can be improved OMRON E5CN-HTQQ203D-FLK.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV.
By supporting software (Ver.4.0 CX-Thermo) to carry out a simple function (AND/OR logic and delay),
Be able to execute flexible contact output.
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay fault.
Position ratio type. Size: 1/16 DIN 48 × 48 × 78 (W × H × D).
Power supply voltage: 100 to 240 VAC.
Input type: Thermocouple or Resistance thermometer.
Alarm output: 2.
option units Mounting: No.
Control output: Relay output.
Previous mode: E5CZ-R2.
This Best-selling General-purpose,
48×48-mm Temperature Controller,
Is Now Even Better.
Controllers now available with analog inputs.
Faster sampling at 250 ms.
Transfer output provided for easy output to recorders.
Modelss available with a loop break alarm (LBA) and,
heater short alarm (HS alarm) E5CN-HTQQ203D-FLK.
Easy setting with 11-segment displays.
Setting protection indicator informs operator when,
protection is enabled.
Manual output provided.
New protoocol called Modbus is installed in the models,
with communications E5CN-HTQQ203D-FLK.
USB-Serial conversion cable is available.
Note: Refer to Precautions on page 33.


...More relevant models >>>>