LK Automation Limited LK Automation Limited
Brand: OMRON
Go Back >> Product Catalogues
E5CN-HTV201D-FLK | OMRON Programmed temperature controller E5CN-HTV201D-FLK
OMRON E5CN-HTV201D-FLK Manual And Instructions
E5CN-HTV201D-FLK datasheetPDF datasheet
E5CN-HTV201D-FLK Programmable TypeBasic Type
E5CN-HTV201D-FLK Programmable TypeUser's Manual
E5CN-HTV201D-FLK User's Manual
E5CN-HTV201D-FLK Basic TypeBasic Type
E5CN-HTV201D-FLK User's Manual
E5CN-HTV201D-FLK User's Manual
E5CN-HTV201D-FLK Communications FunctionsUser's Manual
E5CN-HTV201D-FLK USER'S MANUAL
E5CN-HTV201D-FLK Communications FunctionsUser's Manual
E5CN-HTV201D-FLK USER'S MANUAL
E5CN-HTV201D-FLK INSTRUCTION Manual

OMRON E5CN-HTV201D-FLK Product information and technical parameters:
Brand: OMRON
Name: Programmed temperature controller
Model: E5CN-HTV201D-FLK
Size: 48 * 48mm, terminal type.
Type: control output 1 point type (power AC/DC24V).
Shell color: black.
Control output: linear voltage output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: -.
Event input points: -.
Transfer output: output (using control output).
Communication: RS-232C.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms.
Full of all models (capable of thermocouple /Pt/ analog input switching),
1 machines to support a variety of sensors.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm),
Interactive display PV/SV.
By supporting software (Ver.4.3 CX-Thermo),
In simple arithmetic functions (AND/OR logic and delay).
Setting the program settings that can perform flexible contact output.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller.

Control output: relay output.
Auxiliary output: 2 points.
Heating wire break, SSR fault detection function: -.
Event input: -.
Communication: RS-485.
Terminal shape: main unit (no terminal unit).
Power supply voltage: AC100 ~ 240V.
DIN rail operation, high performance E5 / C series of the maintenance of the most suitable system connected with a touch screen /PLC and thermostat installation type OMRON E5CN-HTV201D-FLK E5CN-HTV201D-FLK
DIN 85mm * 22.5MM width depth guide installation type, housed in the control cabinet of the thin slender body.
The terminal platform can be easily replaced, and the maintenance performance is improved.
Through the 50ms high speed sampling, suitable for the use of high speed heating.
Easy to connect with PLC through no program communication OMRON E5CN-HTV201D-FLK.
The use of communication adapter cable (sold separately) connected to the computer, without power supply connection
Set up。 It can be easily set by CX-Thermo (sold separately).
With auxiliary output (maximum 2 points), event input (maximum 1 points), the basic function is complete.
The confirmation of a simple, eye-catching white PV display when starting or abnormal in the cabinet
(PV high 8 OMRON E5CN-HTV201D-FLK. 5mm). Size: 48 x 96mm.
Control output 1: relay output (open).
Control output 2: relay output (off).
Auxiliary output: -.
Communication mode: -.
Heater disconnection: -.
Event input: -.
Plug in terminal.
Potentiometer input: there.
Power supply voltage: AC100 ~ 240V.
New highlight LCD panel, font larger, display more clearly integrated low power design,
Longer life performance stability,
Perfect function of proportional valve control special (some models have no potentiometer input virtual opening function)
E5AC-PR-800 white LCDPV display height to reach 25mm, greatly improve the visibility.
The main body is short, and the diameter is only 60mm.
50ms high speed sampling period. Size: 48 x 24mm.
Control output 1: linear current output.
Control output 2:--.
Auxiliary output: 1 points.
Power supply voltage: AC100 ~ 240V.
Terminal type: PUSH-IN fastening terminal table type.
Input category: full range multi input.
Heater break, SSR fault detection function: -.
Communication: RS-485.
Event input: -.
A small body of 48 * 24mm specifications on the condensation operation, E5_C series of high performance.
Slender body width 48mm * 24mm * 90mm high depth,
The most suitable for small devices / physical and chemical equipment, etc..
Although the small size, but also through the character of the high 10.5mm white PV display to achieve high recognition.
The terminal stage is adopted to disassemble and assemble the structure, which improves the maintenance performance.
The coonnection method can be selected from a screw terminal and a PUSH-IN fastening terminal E5CN-HTV201D-FLK.
High speed sampling of 50ms is realized.
Easy to connect with PLC through no program communication.
The use of electric communication converrsion Village (sold separately) connected to the computer after,
No power connection can be set E5CN-HTV201D-FLK.
It can be easily set by CS-Thermo (sold separately).


...More relevant models >>>>