E5CN-R2H03T-FLK | OMRON Foundation type temperature controller E5CN-R2H03T-FLK
OMRON E5CN-R2H03T-FLK Manual And Instructions
E5CN-R2H03T-FLK datasheetPDF datasheet
E5CN-R2H03T-FLK datasheetPDF datasheet
E5CN-R2H03T-FLK datasheetPDF datasheet
E5CN-R2H03T-FLK Basic TypeUser's Manual
E5CN-R2H03T-FLK User's Manual
E5CN-R2H03T-FLK User's Manual
E5CN-R2H03T-FLK Communications FunctionsUser's Manual
E5CN-R2H03T-FLK USER'S MANUAL
E5CN-R2H03T-FLK Communications FunctionsUser's Manual
E5CN-R2H03T-FLK USER'S MANUAL

OMRON E5CN-R2H03T-FLK Product information and technical parameters:
Brand: OMRON
Name: Foundation type temperature controller
Model: E5CN-R2H03T-FLK
The main body: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: single phase heater with detection function.
Event input points: -.
Transfer output: -.
Communication: RS-485.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Further performance improvement.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.

Size: 48 x 48mm.
Control output 1: relay.
Auxiliary (alarm) output: 3.
Transfer output: -.
Event input: -.
Communication: -.
Break detection: -.
Power supply voltage: DC24V/AC24V.
The white PV (current value) with excellent visibility shows the segment to make the confirmation work more easily OMRON E5CN-R2H03T-FLK.
Eye-catching white + industry''s largest display size
The black and white display and the industry''s largest display size to achieve excellent visibility E5CN-R2H03T-FLK
No matter from which angle or in the natural lighting environment, the dark scene,
Can quickly and accurately confirm the current value.
Displays the current value (PV/ white), the target value (SV/ green) and the progress of the program (PRG, SEG/ yellow) OMRON E5CN-R2H03T-FLK.
Can be viewed at the same time, there is no need to switch the display, so as to improve the efficiency of operations. Terminal type: Exposed-lead Models.
Protective tubing diameter D(mm): 4.8 dia.
Protective tubing length L: 50 cm.
Lead wire type: Standard.
Lead wire length M: 4m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work OMRON E5CN-R2H03T-FLK.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Size: 96 x 96mm.
Ontology: terminal type, analog input type.
Category: control output 2 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output 1: relay output.
Control output 2: high life relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event entry point: 2.
Transfer output: -.
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automaticc / manual, RUN/STOP, alarm), interactive display PV/SV E5CN-R2H03T-FLK.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which cann display the current value / target / operation E5CN-R2H03T-FLK.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation.


...More relevant models >>>>