LK Automation Limited LK Automation Limited
Brand: OMRON
Go Back >> Product Catalogues
E5CN-R2PHT | OMRON Foundation type temperature controller E5CN-R2PHT
OMRON E5CN-R2PHT Manual And Instructions
E5CN-R2PHT datasheetPDF datasheet
E5CN-R2PHT datasheetPDF datasheet
E5CN-R2PHT Basic TypeUser's Manual
E5CN-R2PHT User's Manual
E5CN-R2PHT User's Manual
E5CN-R2PHT Communications FunctionsUser's Manual
E5CN-R2PHT USER'S MANUAL
E5CN-R2PHT Communications FunctionsUser's Manual
E5CN-R2PHT USER'S MANUAL

OMRON E5CN-R2PHT Product information and technical parameters:
Brand: OMRON
Name: Foundation type temperature controller
Model: E5CN-R2PHT
The main body: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: single phase heater with detection function /ES1B power supply.
Event input points: -.
Transfer output: -.
Communication: -.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Further performance improvement.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.

Control output: voltage output (SSR driver).
Auxiliary output: 2 points.
Heating wire break, SSR fault detection function: -.
Event input: -.
Communication: RS-485.
Terminal shape: screw terminal table type (main unit + terminal unit).
Power supply voltage: AC/DC24V.
DIN rail operation, high performance E5 / C series of the maintenance of the most suitable system connected with a touch screen /PLC and thermostat installation type OMRON E5CN-R2PHT E5CN-R2PHT
DIN 85mm * 22.5MM width depth guide installation type, housed in the control cabinet of the thin slender body.
The terminal platform can be easily replaced, and the maintenance performance is improved.
Through the 50ms high speed sampling, suitable for the use of high speed heating OMRON E5CN-R2PHT.
Easy to connect with PLC through no program communication.
The use of communication adapter cable (sold separately) connected to the computer, without power supply connection
Set up。 It can be easily set by CX-Thermo (sold separately).
With auxiliary output (maximum 2 points), event input (maximum 1 points), the basic function is complete.
The confirmation of a simple, eye-catching white PV display when starting or abnormal in the cabinet
(PV high 8 OMRON E5CN-R2PHT. 5mm). Size: 48 * 48mm, terminal type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: linear voltage output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: -.
Event input points: -.
Transfer output: output (using control output).
Communication: RS-232C.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms.
Full of all models (capable of thermocouple /Pt/ analog input switching),
1 machines to support a variety of sensors.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm),
Interactive display PV/SV E5CN-R2PHT.
By supporting software (Ver.4.3 CX-Thermo),
In simple arithmetic functions (AND/OR logic and delay).
Setting the program settings that can performm flexible contact output E5CN-R2PHT.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller.


...More relevant models >>>>