LK Automation Limited LK Automation Limited
Brand: OMRON
Go Back >> Product Catalogues
E5CN-Y2H03T-FLK | OMRON Foundation type temperature controller E5CN-Y2H03T-FLK
OMRON E5CN-Y2H03T-FLK Manual And Instructions
E5CN-Y2H03T-FLK datasheetPDF datasheet
E5CN-Y2H03T-FLK datasheetPDF datasheet
E5CN-Y2H03T-FLK datasheetPDF datasheet
E5CN-Y2H03T-FLK Basic TypeUser's Manual
E5CN-Y2H03T-FLK User's Manual
E5CN-Y2H03T-FLK User's Manual
E5CN-Y2H03T-FLK Communications FunctionsUser's Manual
E5CN-Y2H03T-FLK USER'S MANUAL
E5CN-Y2H03T-FLK Communications FunctionsUser's Manual
E5CN-Y2H03T-FLK USER'S MANUAL

OMRON E5CN-Y2H03T-FLK Product information and technical parameters:
Brand: OMRON
Name: Foundation type temperature controller
Model: E5CN-Y2H03T-FLK
The main body: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: relay output and long life.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: single phase heater with detection function.
Event entry point: 2.
Transfer output: -.
Communication: -.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Further performance improvement.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.

Size: 96 x 96mm.
Control output 1: voltage output (SSR driver).
Control output 2: voltage output (SSR driver).
Auxiliary output: 4 points (auxiliary output 2, 1 common, auxiliary output 3, 4 public general).
Power supply voltage: AC100 ~ 240V.
Terminal shape: screw terminal table type.
Input category: full range multi input OMRON E5CN-Y2H03T-FLK.
Heating wire break, SSR fault detection function: 1 points E5CN-Y2H03T-FLK
Communication: RS-485.
Event input: 2 points.
Remote SP input: -.
Transfer output: -.
Large screen display white PV legible. From selection to setting and operation are simple and easy to use.
Full capacity, function and performance of I/O. Suitable for more applications.
E5AC white LCDPV display height is about 25mm OMRON E5CN-Y2H03T-FLK.
The upper panel and the front panel are equipped with tool ports.
With the communication conversion line (sold separately) connected to the computer to establish the controller without the need to install the wire for power supply.
Easy to install CX-Thermo (sold separately).
50ms high speed sampling period.
Model can be equipped with up to 4 point auxiliary output, 6 point event input,
1 point transfer output and remote SP input, suitable for a wide range of applications OMRON E5CN-Y2H03T-FLK.
The main body is short, the thickness is only 60mm.
Easy to use programmable logic controller (PLC) is connected to the programmable logic controller (PLC).
The temperature controller is connected to each other by using the component communication.
A new type of proportional control allows you to control the valve. Size: 45 × 35 mm.
Type: Plug-in.
Control method: ON/OFF operation.
Control output: Relay.
Power supply voltage: 100 to 240 VAC.
Ideal for Simple Built-in Control.
A high switching capacity of 10 A at 250 VAC enables,
direct load switching.
A sensor is provided to enable immediate application.
Sockets with finger protection (PTF14A-E) or without,
finger protection (PTF14A) can be used.
Simple operation and settings. Even simpler with digital models. Size: 96 x 96mm.
Control output 1: relay output.
Control output 2:--.
Auxiliary output: 2 independent points.
Power supply voltage: AC100 ~ 240V.
Terminal shape: screw terminal table type.
Input category: full range multi input.
Heating wire break, SSR fault detection function: -.
Communication: -.
Event input: -.
Remote SP input: -.
Transfer output: -.
Large screen display white PV legible. From selection to setting and operation are simple and easy to use.
Full capacity, function and performance of I/O. Suitable for more applications.
E5AC white LCDPV display height is about 25mm.
The upper panel and the front panel are equipped with tool ports.
With the communication conversion line (sold separately) connected to the computer to establish the controller without the need to install the wire for power supply.
Easy to install CX-Thermo (sold separately).
50ms high speed sampling period.
Model can be equipped with up to 4 point auxiliary output, 6 point event input,
1 point transfer output annd remote SP input, suitable for a wide range of applications E5CN-Y2H03T-FLK.
The main body is short, the thickness is only 60mm.
Easy to use programmable logic controller (PLC) is connected to the programmable logic controller (PLC).
The temperrature controller is connected to each other by using the component communication E5CN-Y2H03T-FLK.
A new type of proportional control allows you to control the valve.


...More relevant models >>>>
Last one: OMRON E5CN-Y2T
next one: OMRON E5CN-Y2HBT