LK Automation Limited LK Automation Limited
Brand: OMRON
Go Back >> Product Catalogues
E5ER-TQ4B | OMRON Program type digital regulator E5ER-TQ4B
OMRON E5ER-TQ4B Manual And Instructions
E5ER-TQ4B datasheetPDF datasheet
E5ER-TQ4B datasheetPDF datasheet
E5ER-TQ4B SETUP MANUAL
E5ER-TQ4B Communications Manual
E5ER-TQ4B User's Manual
E5ER-TQ4B INSTRUCTION Manual

OMRON E5ER-TQ4B Product information and technical parameters:
Brand: OMRON
Name: Program type digital regulator
Model: E5ER-TQ4B
Ontology: program type.
Size: 48 x 96mm.
Type: basic type (1 input).
Control mode: standard control, heating and cooling control.
Output (control / transfer) points: 2 points (pulse + pulse / current).
Output (SUB) points: 4 points.
Event entry point: 2.
Serial communication: -.
New high speed, high precision digital regulator (Cheng Xuxing)!
Can be set up to 32 kinds of procedures.
1 units can be coordinated to run up to 4 channels.
High speed acquisition of 50ms.
With CX-Thermo on the computer easily set.

Control output 1: Relay output.
Auxiliary output: Two.
Communications: --.
Heater burnout: One.
Event inputs: Two.
Power supply voltage: 24 VAC/VDC.
Large White PV Display That’s Easier to Read.
Easy to Use, from Model Selection to,
Setup and Operation.
A Complete Range of I/O Capacities,
Functions, and Performance OMRON E5ER-TQ4B.
Handles More Applications.
The white PV display with a height of 15 E5ER-TQ4B2 mm improves visibility.
High-speed sampling at 50 ms.
Short body with depth of only 60 mm.
Easy connections to a PLC with programless communications.
Use component communications to link Temperature.
Controllers to each other. Size: 48 x 48mm.
Body: terminal type.
Type: control output 1 point type (power AC/DC24V) OMRON E5ER-TQ4B.
Shell color: black.
Control output: linear voltage output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
The failure detection function of the heater with the broken line and SSR: -.
Event entry point: 2.
Transfer output: output (special terminal).
Communication: -.
General thermostat new high performance (high resolution, high speed, high precision input) type products OMRON E5ER-TQ4B.
Support simple operation, preventive maintenance, using a new type of liquid crystal, visual angle, contrast to enhance.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms.
All models (thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Add PV/SV state display function, to see the state of the thermostat.
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
By supporting software (CX-ThermoVer.4.0) to carry out a simple function (AND/OR logic and delay),
Be able to execute flexible contact output
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay faultCase color: Black.
Control output: Voltage output (for driving SSR).
Control mode *1: Standard or heating/cooling.
No. of auxiliary outputs: 1.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: 2.
Transfer output *2: --.
Communi cations: --.
Previous model: Thermocouple input, --;
Resistance thermometer input, --.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternate,
between displaying the staatus of the Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV E5ER-TQ4B.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colorrs E5ER-TQ4B.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs.