LK Automation Limited LK Automation Limited
Brand: OMRON
Go Back >> Product Catalogues
E5ER-TQT3DW-FLK | OMRON Program type digital regulator E5ER-TQT3DW-FLK
OMRON E5ER-TQT3DW-FLK Manual And Instructions
E5ER-TQT3DW-FLK datasheetPDF datasheet
E5ER-TQT3DW-FLK datasheetPDF datasheet
E5ER-TQT3DW-FLK SETUP MANUAL
E5ER-TQT3DW-FLK Communications Manual
E5ER-TQT3DW-FLK User's Manual
E5ER-TQT3DW-FLK INSTRUCTION Manual

OMRON E5ER-TQT3DW-FLK Product information and technical parameters:
Brand: OMRON
Name: Program type digital regulator
Model: E5ER-TQT3DW-FLK
Ontology: program type.
Size: 48 x 96mm.
Type: 2 input type.
Control mode: 2 channel standard control /1 channel heating and cooling control /1 channel series control and other functions.
Output (control / transfer) points: 2 points (pulse + pulse / current).
Output (SUB) points: 2 points.
Event entry point: 4.
Serial communication: RS-485.
New high speed, high precision digital regulator (Cheng Xuxing)!
Can be set up to 32 kinds of procedures.
1 units can be coordinated to run up to 4 channels.
High speed acquisition of 50ms.
With CX-Thermo on the computer easily set.

Control output 1: Relay output.
Control output 2: Relay output.
Auxiliary output: Two.
Communications: RS-485.
Heater burnout: One.
Event inputs: Two.
Power supply voltage: 100 to 240 VAC.
Large White PV Display That’s Easier to Read.
Easy to Use, from Model Selection to Setup and Operation.
A Complete Range of I/O Capacities,
Functions, and Performance OMRON E5ER-TQT3DW-FLK.
Handles More Applications E5ER-TQT3DW-FLK
The white PV display with a height of 15.2 mm improves visibility.
High-speed sampling at 50 ms.
Short body with depth of only 60 mm.
Easy connections to a PLC with programless communications.
Use component communications to link Temperature,
Controllers to each other. Control output: Voltage output OMRON E5ER-TQT3DW-FLK.
Auxiliary output: Two.
Communications: RS-485.
Heater burnot: Detection for Single-phase heater.
Event inputs: --.
Power supply voltage: 24 VAC/VDC.
The E5DC-800 Mounts to DIN Track and Is Ideal,
for Connections to HMIs and PLCs.
It provides the Same Easy Operation and,
Advanced Performance as the Rest of the,
E5@C-800 Series.
A slim body at 85 × 22.5 mm (D × W) that fits into narrow control,
panels and mounts to DIN Track OMRON E5ER-TQT3DW-FLK.
Removable terminal block for easy replacement to simplify maintenance.
High-speed sampling at 50 ms for applications with high-speed,
temperature increases.
Easy connections to a PLC with programless communications.
Models are available with up to 2 auxiliary outputs and 1 event input to,
complete basic functions.
A white PV display (height: 8.5 mm) is easy to read when setting up,
checking alarms, and making settings in a control panel. Size: 96 x 96mm.
Type: power AC/DC24V with.
Shell color: black.
Control output 1: built-in SSR output.
Control output 2: built-in SSR output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
The detection function of the broken wire and SSR fault of heater: detection function of single phase or three phase heater.
Event entry point: 2.
Transfer output: -.
Remote SP:4 to 20mA input.
Communication: RS-422.
General thermostat new high performance (high resolution, high speed, high precision input) type products.
Support simple operation, preventive maintenance.
A new type of liquid crystal, which can communicate with the front through the infrared port, is adopted,
Visual angle, contrast can be improved.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV status display function, convenient to checck the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV E5ER-TQT3DW-FLK.
By supporting software (Ver.4.0 CX-Thermo) to carry out a simple function (AND/OR logic and delay),
Be able to execute flexible contact output E5ER-TQT3DW-FLK.
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay fault.
Position ratio type.