Name: HFU (gradient temperature control) (See note 1.).
Power supply voltage: 24 VDC supplied from the End Unit.
No. of control points: None.
Control outputs 1 and 2: None.
Control outputs 3 and 4: None.
Auxiliary output: Transistor output: 4 points (sourcing).
Functions: Heater burnout alarm, None; Event inputs, 4.
Communications functions: From End Unit, Port A, RS-485; Port C, RS-422.
Input type: No input.
Terminal: Screw-less clamp.
Gradient Temperature Control to Achieve.
Consistent Layer Temperature.
Perform gradient temperature control ranging from 2 to 32 channels.
groups, or 32-channel gradient temperature control for up to 2 groups.
Set gradient temperature control or 2-PID control for each group.
connections to Programmable Controllers. (The same feature,
as Standard-control EJ1 Models.).
using optimum cycle control for high-accuracy control with minimal noise.
Size: 48 * 48mm, terminal type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: linear voltage output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: -.
Event input points: - OMRON EJ1G-HFUB-NFL2.
Transfer output: output (using control output).
Communication: -.
New program type
EJ1G-HFUB-NFL2
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms OMRON EJ1G-HFUB-NFL2.
Full of all models (capable of thermocouple /Pt/ analog input switching),
1 machines to support a variety of sensors.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm),
Interactive display PV/SV.
By supporting software (Ver.4.3 CX-Thermo),
In simple arithmetic functions (AND/OR logic and delay).
Setting the program settings that can perform flexible contact output OMRON EJ1G-HFUB-NFL2.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller. Terminal type: Exposed-lead Models.
Protective tubing diameter D (mm): 6.4 dia. .
Protective tubing length L: 20cm.
Lead wire type: Standard.
Lead wire length M : 2m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Terminal type: Exposed-lead Models.
Protective tubing diameter D (mm): 1.6 dia.
Protective tubing length L: 15cm.
Lead wire type: Standard.
Lead wire length M : 2m.
A Wide Variety of High-precision.
Tempperature Sensors EJ1G-HFUB-NFL2.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Teemperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal EJ1G-HFUB-NFL2.