LK Automation Limited LK Automation Limited
Brand: OMRON
Go Back >> Product Catalogues
ES1-LW50 | OMRON Non contact temperature sensor ES1-LW50
OMRON ES1-LW50 Manual And Instructions
ES1-LW50 INSTRUCTION Manual

OMRON ES1-LW50 Product information and technical parameters:
Brand: OMRON
Name: Non contact temperature sensor
Model: ES1-LW50
Type: medium and low temperature.
Measuring temperature range: - 50 ~ +500 C.
The target size: 40mm diameter (from 500mm).
No need to contact the workpiece, you can measure the temperature.
Achieve no damage, health and efficient temperature management.
A small spot diameter 3mm and 8mm diameter two types.
Reproduction of positive and negative 0.5 degrees Celsius, response speed of 0.4 seconds,
(95%) with high precision and high speed measurement.
In addition to the original middle temperature (0 ~ +500 C),
Also added in low temperature (- 50 DEG C ~ +500),
High temperature (0 ~ +1000 degrees C) models.
New measurement distance up to 500mm, 1000mm long distance type.
Use another programmer, can change the temperature monitoring, radiation rate,
Moving average function and output range.
(picture for the installation of programmer in the ES1 body)

Classification: General purpose Models.
Description: Standard thermocouple.
Temperature range (See note 3.): 0°C to 1,400°C.
Element type: R (PR).
Conductor type: Non grounded type.
Class: 2 (0.25).
Protective tubing material: JIS ceramic JIS special ceramic.
Terminal type: Enclosed terminals OMRON ES1-LW50.
Page: 16.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work ES1-LW50
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal OMRON ES1-LW50. Name: Basic Unit (temperature control) *1.
Power supply voltage: 24 VDC supplied from the End Unit.
No. of control points: 2.
Control outputs 1 and 2: Voltage output: 2 points (for SSR drive) *2.
Control outputs 3 and 4: Transistor output: 2 points (sinking).
Auxiliary output: None.
Functions: burnout Heater alarm, 2 *3; Event inputs, 2 .
Communications functions: G3ZA connection port: RS-485,
From End Unit: Port A or port B: RS-485 OMRON ES1-LW50.
Input type: Thermocouple, platinum resistance thermometer,
analog voltage, and analog current selectable for each channel.
Terminal: Screw-less clamp.
In-panel Temperature Controller with Flexible,
Modular Design and Wide Integration with Host,
Devices.
The compact modular structure enables construction of temperature,
systems optimally suited to the application.
Connection can be made to a Programmable Controller without any,
programming required, reducing the number of steps required in ladder,
programming design.
One fully universal-input Unit includes a thermocouple, platinum-resistance,
thermometer, and analog input for easy selection and reduced inventory,
requirements.
Connect direcctly to the G3ZA Multi-channel Power Controller using,
optimum cycle control for high-accuracy regulation with minimal noise ES1-LW50.
Autotuning (AT) can be used for independent heating/cooling PID control.
Self-tuning (ST) can be used to calcullate the PID constants with the step,
response method ES1-LW50.
Up to 16 Temperature Controllers can be connected to a single DeviceNet,
Communications Unit.


...More relevant models >>>>